demig Prozessautomatisierung GmbH
Manual Terminal DE-BT 1000
Chapter: Introduction
•
5
1.3.1.3.
Factory Settings
To set the terminal back to factory setting, use the shortcut
[SHIFT] + [F1]
in the
configuration menu. In case the security request is answered with
„Yes“
the DE-BT
1000 is set back to factory settings. The factory settings are as follows:
•
GID = 1
•
UID = 1
•
Baud rate RS485 = 9600
•
Parity RS485 = o
•
Stop bits RS485 = 2
•
Baud rate RS232 = 9600
•
Parity RS232 = o
•
Stop bits RS232 = 2
•
Active = RS485
•
Port number = 50000
•
DHCP = Yes
•
IP address = 0.0.0.0
•
Subnet mask = 255.255.255.0
•
Default gateway = 0.0.0.0
1.3.1.4.
Information Display
Information about the preset configuration can be displayed by
[SHIFT] + [F2]
in the
configuration menu in case, the request was confirmed with
„Yes“
. Besides this
information, also the current network configuration is shown.