2. Safety and protection information
MERMAID E1100-I
STD00
Page 13 of 54
2. Safety and protection information
General safety
Machine Noise:
It is recommended to put on ear protection equipment, etc. ear plug or ear muffler to protect the
user from pro-long under high noise environment.
Recoil Force of Trigger Gun:
Based on calculated value, there will be a recoil force of
99~133N
acting
on the trigger gun to the user. Therefore, a shoulder rest is provided with
every machine. Holding a trigger gun in a correct position will prevent any unnecessary injuries
as shown.
Trigger Gun Vibration:
The declared vibration emission value
a
hd
is 6.3 m/s
2
with an uncertainty
K of 1.1 m/s
2
”.
Pro-
long working with the trigger gun will cause tiredness to the user. It is recommended to work
with the trigger gun not more than 20min continuously.
EAR PROTECTOR EQUIPMENT
must be worn at all time when
using the machine. This is to prevent user from hearing related injuries.
Noise warning sticker can be found on the machine to warn high noise
emission values
Shoulder Rest
Trigger Gun
Complete
CAUTION
Be more caution when using the trigger gun. Shoulder rest is for the user
to rest its trigger gun on its own body weight to counter react to the recoil
force created by the trigger gun. Release any residual pressure from the
gun when the machine is shut down.
CAUTION
Caution must be observe when working with trigger gun. Do not work
continuously without rest in between jobs. Release any residual pressure
from the gun when the machine is shut down
Summary of Contents for MERMAID E1100-I
Page 38: ...4 Spare parts list MERMAID E1100 I STD00 Page 37 of 54 Pump assembly ...
Page 46: ...4 Spare parts list MERMAID E1100 I STD00 Page 45 of 54 ...
Page 47: ...4 Spare parts list MERMAID E1100 I STD00 Page 46 of 54 ...
Page 53: ...5 Wiring Diagram MERMAID E1100 I STD00 Page 52 of 54 5 Wiring Diagram ...