3. Maintenance and troubleshooting
MERMAID E1100-I
STD00
Page 28 of 54
Insert the H.P. packing (fig.34, position 1) ; considered the slight interference between the seal and the
liner, to avoid damage. Before inserting them into their seats, the H.P. seals must be lubricated with
silicone grease.
Insert the anti-extrusion ring(fig.37/39,position 2)
and the gasket bush(fig.37/ 39,position 3)
The gasket bush (fig.38/ 39
, position 3)
must be introduced into the liner with the outlets facing outwards (crankcase side)