c. Phase lack protection
:
when any phase current lacks phase, the acting time
≤
2s
;
d. Imbalance protection
:
when the difference between two phase reach 60
~
75% , the acting time
≤
5s
;
e. As for the protecting characteristic of overloading inverse time lag (time unite is second), please see the
below form. Multiple
=
I actual value
/
I set value.
When the motor running current is more than or equal to 1.2 times the current set to 3.0 times, deferred
action according to the overloaded multiple and actuation in below table
I actual/I set
Time parameter
≥
1.2
≥
1.3
≥
1.5
≥
1.6
≥
2.0
≥
3.0
Acting time
60
48
24
8
5
1
Table 2
、
The curve form of motor protection inverse time lag
H. Temperature protection
:
when detecting the actual temperature greater than the set temperature , the
acting time
≤
2s
;
I. Output relay switch contactor capacity
:
250V5A
;
contactor life is 500000 times
;
J. Current display error is less than1.0%.
;
K.RS
—
485communication.
Three
.
.
.
.
Type and specification
A. Model Instruction
MAM—KY02S
(
(
(
(
40
)
(
)
(
)
(
)
(
B
)
(
)
(
)
(
)
(
T
)
)
)
)
—
Ⅷ
Ⅷ
Ⅷ
Ⅷ
VIII Control mode
Ⅷ
Ⅷ
Ⅷ
Ⅷ
T
:
with RS—485 communication
B
:
transmitter; K
:
pressure switch
Adaptive main motor maximum normal working current
V
:
Vane air compressor
;
S
:
Screw air compressor
02 type air compressor controller
(
LCD Chinese display
)
Product series
B. Adaptive motor power specification table
Parameter
standard
current range
(
A
)
Adaptive
main motor
power
(
KW
)
remark
Introduction
MAM—KY02S
(
20
)
8
~
20
4
~
10
MAM—KY02S
(
40
)
16
~
40
8
~
20
MAM—KY02S
(
100
)
30
~
100
15
~
50
MAM—KY02S
(
200
)
80
~
200
40
~
100
MAM—KY02S
(
400
)
160
~
400
80
~
200
Fan current contains
0.2~2.5A grade
、
1~5Agrade, and 4~10A
grade. The three kinds
of current are