A. User parameter and function of variable frequency air compressor
First class Menu
Second class Menu
Initial setting
value
Function
Pressure upper bound
*.**MPa
Download pressure value
Pressure lower bound
*.**MPa
Upload pressure value
Fan start temperature
***
℃
Control fan starting
Fan stop temperature
***
℃
Control fan stopping
Variable frequency
working pressure
*.**MPa
Motor rated power
*.**KW
pressure
and
temperature
Preset
Rated rotation speed
(
50HZ)
*.**RPM
Air-end start time
0008 Second
Controller protects motor to avoid
striking current when motor starts.
Fan start time
0006 Second
Controller protects motor to avoid
striking current when motors starts.
Star-angle delay time
0006 Second
Star-triangle decompression start delay
time
Upload delay time
002 Second
Delay uploading time after star-triangle
decompression start
unload delay time
0005 Minute
The deadhead continuing runtime, over
which time the machine will
automatically stop
Stop delay time
0010 Second
When shut down, don’t stop the machine
until delay the time after the deadhead.
Start delay time
0100 Second
Restart after delaying the time when the
deadhead’s overlong stop.
Variable frequency
rising speed
625
On-off
time-delaying
preset
Variable frequency
decreasing speed
625
On-off mode
Machine side
Set as transport distance, the machine
side key and remote switch can start and
stop the equipment
Uploading mode
Automatic
Set as manual state, only press the key
to control Uploading/downloading
operation mode
Preset
Communication mode
Forbidden
Set as forbidden, the Communication is
useless.