Shanghai Denair Compressor Co.,Ltd.
www.denaircompressor.net 45/48
f. Failure on air compressor
f. Manual operates the machine, if unable to
rotate it, please contact our service
department.
a. Too high air
consumption( the pressure is
operating under the set value)
a. Check the air consumption and if
necessary, please increase the number of
compressor.
b. The air filter is blocked
b. Clean or replace
c. Air intake valve bad action
(butterfly valve is blocked and
can't do action)
c. Dismantle and clean the air intake valve
and fill lubricating grease.
Three
.
Operating current lower
than the normal value
d. Air flow regulating valve
improper adjustment
d. Reset and readjust
a. Too high cooling water
volume
a. Adjust the outlet valve of cooling water, if
it is caused by air-cooling cooler, please
reduce the cooler heat dissipating area.
b. Low environmental
temperature
b. Adjust the outlet valve of cooling water, if
it is caused by air-cooling cooler, please
reduce the cooler heat dissipating area.
c. Too long zero load
c. Increase the air consumption
d. Wrong air delivery
temperature form
d. Replace the air delivery temperature form
Four
.
Exhaust temperature lower
than normal value (75
℃
)
e. Heat control valve failure
e. Replace the heat control valve
a. Insufficient lubricating oil
a. Check the oil level, if it is lower than "L",
please stop the compressor and fill oil to
"H".
b. Insufficient cooling water
volume
b. Check the temperature difference
between inlet and outlet water pipe.
c. Cooling water temperature
becomes higher
c. Check the inlet water temperature
d. High environmental
temperature
d. Increase the air delivery and lower the
room temperature.
e. Oil cooler blocked
e. Check the inlet and outlet water pipe
temperature difference, and the normal
temperature is 5
℃
, if lower that 5
℃
, the oil
cooler may be blocked, so dismantle it and
clean it by drug.
f. Wrong lubricating oil
specification
f. Check the oil number, replace oils and
refer to the 5-1 section.
Five
.
High exhaust temperature,
the air compressor trip operation,
and
the
exhaust
high-temperature indicating valve
lamp on
g. Temperature control valve
g. Check whether the oil is cooled by oil