Shanghai Denair Compressor Co.,Ltd.
www.denaircompressor.net 47/48
Notice: a. Air compressor maintenance personnel must have relative maintenance certification.
b. No right to enjoy the free maintenance service if products are damaged by not using the original
spare parts.
b. Bad action of air inlet valve
valve and fill lubricating grease.
c. Bad action of
pressure-maintenance valve
c. After dismantle, check the valve seat
and the non-return flap valve block to find
whether it is damaged, if so, replace them
or replace the weary spring.
d. Blocked oil-gas separator
d. Check it
,
and if necessary, replace it.
Nine
.
Air volume of compressor
lower than the normal value
e. Discharge solenoid valve leakage
e. Check it
,
and if necessary, replace it.
a. Pipeline leaking
a. Check the leaking position and lock it.
b. Small set pressure value of
empty and over load
b. Reset it ( the common differential
pressure value is 0.1MPa
)
Ten. Frequent empty and over
load
c. Unstable air consumption
c. Increase the air receiver volume
a. Oil stop valve leakage
a.Check it
,
and if necessary, replace it.
b. Non-return flap valve leakage
b. After dismantling it, please check
whether the valve block and valve seat is
worn or not, if so, replace them.
c. Stop the machine when over load
c. Check the air inlet valve is blocked or
not, if so, clean it and fill lubricating oil into
it after dismantlement.
d. Wrong electric line
d. Ask the electric worker to examine and
replace it.
e. Pressure maintenance valve
leakage
e. Check it
,
and if necessary, replace it.
Eleven
.
Oil mist emit from the air
filter when stop the machine
.
f. Irreleasing discharge valve
f. Check the discharge valve and if
necessary, replace it.