.2 Intended use
The bio.x parts cleaning unit is used to clean oil and grease from work pieces in an efficient, environmen-
tally sustainable way using exclusively cleaning fluids authorised by DENIOS.
Other detergents such as degreasers or alkali cleaning agents must
not
be used!
Solvents, disinfectants, alkali or acidic fluids, carburettor and diesel fuels or turpentine must not be
poured into the appliance.
3.3 How it works
A pump feeds the cleaning fluid to the three-way stopcock and the cleaning brush. An air pump ensures a
good supply of oxygen for the cleaning fluid.
Air pump and heater are running continuously.
The heating is controlled via an integrated sensor.
When connected to power supply, air pump and heater are switched on.
4. Initial Operation
After removing the packaging, check the unit casing and operating components for any possible damage
caused in transit. If such damage is found, do not connect the unit to the mains. Report damage immediately
to the carrier who delivered the unit and to DENIOS AG at the service number indicated above. The original
packaging should be kept.
Place the unit in a dry, stable location as required.
The floor must be level. If necessary, level out any uneven surfaces with suitable shimming material.
4.1 Filling with the cleaning fluid
The unit can be opened at the side for servicing or to fill the tank with fresh
detergent. To do so, lift up the right-hand side of the unit top and prop it up
using the bar you can find inside.
Maintenance position of
stand top (aperture angle
approx. 50°)
The cleaning fluid bio.x is available as ready mix or as concentrate.
Fill the ready mix, 4 canisters per 20l = 80l, or the concentrate, 4 canisters
per 5l added to 70l of water into the tank. (please note the maximum level
marking)
4.2 Electrical connection
The unit is connected to the customer's mains supply via the power cable
and plug.
Mains voltage:
The voltage of the power source has to comply with the
details on the identification place of the appliance
Warning: The mains supply must be fitted with a residual current protective device in accordance with
DIN VDE (Association of German Electricians) 0100! (See section 2)
After connected the unit to the mains air pump and heater are switched on. The warming-up process can take
up to 5 hours, depending on the initial temperature. The operating temperature is set at 41°C in the factory
and can not be changed. You can measure the current temperature of the cleaning fluid with a standard
thermometer. After reaching the operating temperature parts cleaning unit is ready for use.