background image

Get
ting Star

ted

Connections

Oper

ation

Tr

oubleshooting

ENGLISH

Specifications

Network Setup

Make settings for wired LAN.

Network Setup

Make network settings.

Menu tree

 F

Main Setup

Network Setup

a

  Network Information

s

  Network Setup

Network Information

Display network information.

[Items to be checked]

DHCP= ON or OFF

 

IP Address

 

MAC Address

Set
up

•  If you are using a broadband router (DHCP function), there is no need 

to make the settings at “Setting the IP Address” and “Setting the 
Proxy”, since the DHCP function is set to “ON” in the POA-3012CI’s 
default settings.

•  If the POA-3012CI is being used connected to a network without the 

DHCP function, the network settings must be made. In this case, 
some  knowledge  of  networks  is  required.  For  details,  consult  a 
network administrator.

•  If you cannot connect to the Internet, recheck the connections and 

settings (

v

page 8).

•  If you do not understand about Internet connection, contact your ISP 

(Internet Service Provider) or the store from which you purchased 
your computer.

• 

DHCP (Dynamic Host Configuration Protocol)

 :

   These  are  systems  by  which  the  IP  address  and  other  network 

settings  are  automatically  set  for  the  POA-3012CI,  computer, 
broadband router and network devices.

• 

DNS (Domain Name System)

 :

   This  is  a  system  for  converting  the  domain  names  used  when 

browsing  Internet  sites  (for  example,  “www.denon.jp”)  into  the 
IP  addresses  actually  used  for  communications  (for  example, 
“202.221.192.106”).

Wired LAN settings

Use this procedure to configure the Wired LAN settings.

1

 

Connect the LAN cable (

v

page 8).

2

 

Turn on the POA-3012CI (

v

page 17).

 

 POA-3012CI performs automatic network setup due to the DHCP 
function.

 

When  connecting  to  a  network  that  has  no  DHCP  function, 
perform the setting in step 3.

3

 

Set  the  IP  address  at  the  menu  “Network  Setup”  – 
“Network Setup”.

*Network Setup
DHCP

*DHCP
OFF

IP Address
192.168.  0.  1

Subnet Mask
255.255.255.  0

Default Gateway
  0.  0.  0.  1

Primary DNS
  0.  0.  0.  0

Secondary DNS
  0.  0.  0.  0 

q  

Select “DHCP” and press the 

SELECT/ENTER 

knob.

w  

 

Turn  the 

SELECT/ENTER 

knob  to  set  “DHCP”  to  “OFF”,  then 

press the 

SELECT/ENTER

 

knob.

  The DHCP function is disabled.

e  

Input the address.

w

 

Set “OFF”.

e  

Use  the  following  buttons  to  input  the  address  and  press  the 

SELECT/ENTER 

knob.

Button functions when entering address

 

SELECT/ENTER 

knob : Turn ············Select

   

Press ··········Confirm

 

u

 

button :  

Cursor to right

 

 

i

 

button :  

Cursor to left

 

ZONE 6 

button :  

Setting during address entry

 

ZONE 5 

button :  

Cancel entry

 

IP Address

 : 

   Set the IP address within the ranges shown below. The Network 

function cannot be used if other IP addresses are set.

  CLASS A: 10.0.0.0 ~ 10.255.255.255
  CLASS B: 172.16.0.0 ~ 172.31.255.255
  CLASS C: 192.168.0.0 ~ 192.168.255.255

 

Subnet Mask

 : 

   When  connecting  an  xDSL  modem  or  terminal  adapter  directly 

to  the  POA-3012CI,  input  the  subnet  mask  indicated  in  the 
documentation  supplied  by  your  provider.  Normally  input 
255.255.255.0.

 

Default Gateway

 : 

   When connected to a gateway (router), input its IP address.

 

Primary DNS

 

Secondary DNS

 : 

   If there is only one DNS address indicated in the documentation 

supplied by your provider, input it at “Primary DNS”. If there are 
two or more DNS addresses, input the first one at “Secondary 
DNS”.

r  

Press the 

SELECT/ENTER 

knob.

   Setup is complete.

When  connecting  to  the  network  via  a  Proxy  server,  select 
“Proxy” and press the 

SELECT/ENTER 

knob (

v

page 16 “Proxy 

settings”).

Select “DHCP”.

1.POA-3012CI_ENG.indd   18

2008/04/08   9:25:49

Summary of Contents for 3012CI - Power Amplifier

Page 1: ...MULTI CHANNEL POWER AMPLIFIER POA 3012CI Owner s Manual Bedienungsanleitung 1 POA 3012CI_ENG indd 1 2008 04 08 11 49 58...

Page 2: ...ng sollte auf keinen Fall durch das Abdecken der Bel ftungs ffnungen durch Gegenst nde wie beispielsweise Zeitungen Tischt cher Vorh nge o behindert werden Auf dem Ger t sollten keinerlei direkte Feue...

Page 3: ...ds EN60065 EN55013 EN55020 EN61000 3 2 and EN61000 3 3 Following the provisions of 2006 95 EC and 2004 108 EC Directive BEREINSTIMMUNGSERKL RUNG Wir erkl ren unter unserer Verantwortung da dieses Prod...

Page 4: ...e between the inside of the unit and the surroundings condensation dew may form on the operating parts inside the unit causing the unit not to operate properly If this happens let the unit sit for an...

Page 5: ...N STANDBY 17 w Power indicator 17 e Display 17 q Information display Displays present status information and Setup menu etc r ZONE select buttons 10 t ZONE operation mode indicators 6 13 y SETUP butto...

Page 6: ...or 8 w RS 232C connector 9 e Speaker terminals SPEAKER SYSTEMS 5 r AC inlet AC IN 10 t AUDIO INPUT connectors 7 y TRIGGER IN jacks 9 u MASTERTRIGGER OUT jack 9 i BUS INPUT connectors 7 o BUS OUTPUT co...

Page 7: ...some types of connections certain settings must be made on the POA 3012CI For details refer to the instructions for the respective connection items below Cables Used for Connections Select the cables...

Page 8: ...RIDGED out putting a signal input to the AUDIO INPUT terminal input to an even numbered input terminal To select a signal for BRIDGED output from among the signals L R L R input to the BUS INPUT termi...

Page 9: ...pedance lower than specified for example 4 ohms speakers NORMAL MODE are used for an extended period of time with the volume turned up high the temperature may rise activating the protection circuit T...

Page 10: ...nel using INPUT SELECT on the Main Setup menu When BUS L R is used signals input to BUS INPUT L and R are mixed and output as monaural n When Using in NORMAL MODE To play signals input to the AUDIO IN...

Page 11: ...ble used a shielded twisted pair STP cable Do not use an unshielded twisted pair UTP cable as it may exceed noise standard limits For Europe model n Computer A computer with the following specificatio...

Page 12: ...vice If the trigger input level of the connected device is higher than 250 mA 12 V and depending on the short circuiting conditions the POA 3012CI s protection circuit may be activated in which case T...

Page 13: ...se the setting item of another ZONE is not displayed To configure the settings for DIMMER MODE and POWER CONFIGURATION use the SETUP button to select Main Setup mode 1Press the SETUP button The POA 30...

Page 14: ...ON vpage 14 Bright Dim Dark OFF POWER BUTTON ON LINE MASTER TRIGGER BTL AUX 2 BTL BUS L BTL BUS R BTL BUS L R BTL LCF OFF BTL LCF ON BRIDGED NORMAL CH 1 2 CH 3 4 CH 5 6 CH 7 8 CH 9 10 CH 11 12 CH 1 2...

Page 15: ...tup Option Setup vpage 15 vpage 15 vpage 15 vpage 16 IP Address Subnet Mask Default Gateway Primary DNS Secondary DNS Proxy Address Port Main Setup DHCP IP Address Mac Address DHCP ON OFF Address Name...

Page 16: ...see GSelectable ChannelsH in a VOLUME CONTROL Default NORMAL MODE Selectable Channels ON Low frequency component is cut OFF Low frequency component is not cut d LOW CUT FILTER Cuts the low frequency c...

Page 17: ...for about 3 seconds during the operation before reverting to the set brightness Selectable items POWER BUTTON Operate with the ON STANDBY button only ON LINE Operate from an external device via Ether...

Page 18: ...I performs automatic network setup due to the DHCP function When connecting to a network that has no DHCP function perform the setting in step 3 3Set the IP address at the menu Network Setup Network S...

Page 19: ...sional use only This function allows a DENON serviceperson or installer to check the POA 3012CI s status and make settings via the Internet NOTE Only use this function if so instructed by a DENON serv...

Page 20: ...Main Setup menu vpage 13 n To Switch Input Setting Refer to INPUT SELECT on the Main Setup menu vpage 13 Operating the POA 3012CI Using a Browser Web control This function lets you operate the POA 30...

Page 21: ...the web controller may be reset Resetting the Microprocessor Perform this procedure if the display is abnormal or if operations cannot be performed When the microprocessor is reset all the settings a...

Page 22: ...t securely Connect the speaker as required for the Operation Mode NORMAL MODE or BRIDGED MODE Connect the input connector correctly in the case of BRIDGED input for each ZONE input to an even numbered...

Page 23: ...20 1 POA 3012CI_ENG indd 23 2008 04 08 9 25 52...

Page 24: ...Denon Brand Company D M Holdings Inc Printed in Japan 00D 511 4719 004 www denon com 3 POA 3012CI_Backpage indd 1 2008 04 08 9 28 48...

Reviews: