38
• Firm error codes at the main microprocessor rewritten. (Check main microprocessor)
Error Code
Details of Error code
Coping strategies
10
Firm Info response acquisition TimeOut(Main rewrite
Firmware recived failure(TimeOut))
Turn off and on the power. Updating starts automatically.
11
Firm Info response acquisition recived error(Main
rewrite Firmware recived failure(Error)
Turn off and on the power. Updating starts automatically.
12
Firm Info response acquisition recived
error (Main rewirte Firmware recived data
incorrect(CheckSumError))
Turn off and on the power. Updating starts automatically.
13
Rewrite failure (BlockErase failued before Main
rewriting )
Turn off and on the power. Updating starts automatically.
14
Rewrite failure (BlockWrite failued before Main
rewriting)
Turn off and on the power. Updating starts automatically.
15
Rewrite failure (Verify incorrect after Main rewriting)
Turn off and on the power. Updating starts automatically.
36
Login failure(DPMSAccess Login incorrect infomation) Carry out the update in an environment that has little network
load.
37
Login failure(DPMSAccess Server busy infomation)
Carry out the update in an environment that has little network
load.
38
Login failure(DPMSAccess connection failed
infomation)
Check the network connection. Carry out the update in an
environment that has little network load.
39
Login failure(DPMSAccess access TimeOut)
Check the network connection. Carry out the update in an
environment that has little network load.
3A
DownLoad failure(Download error (NG)information
recieved)
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
3B
DownLoad failure(Download error (ServerBusy)
information recieved)
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
3C
DownLoad failure(Download error (connection failed)
information recived)
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
Summary of Contents for CEOL RCD-N8
Page 10: ...10 DIMENSION 299 0 112 0 108 0 35 0 35 0 210 0 280 0 2 0 301 0 218 0 45 0 36 0 30 0 4 0 ...
Page 22: ...22 3 Remove the screws 4 Remove the screws Shooting direction C Shooting direction A ...
Page 24: ...24 4 Remove the screws remove the connector wires CN221 CN222 Shooting direction C ...
Page 84: ...84 PCM9211 MAIN IC103 ...
Page 85: ...85 PCM9211 Block Diagram ...
Page 86: ...86 PCM9211 Pin Discriptions ...
Page 87: ...87 NJM2755 MAIN IC701 NJM2755 Block Diagram ...
Page 93: ...93 L6565 SMPS IC821 L6565 Block Diagram ...
Page 94: ...94 ICE3BR1765J SMPS IC871 ICE3BR1765J Block Diagram ...