Ver 1.00
27 page of 30
1.9.17 Twin
REC
This prepares Twin REC.
byte
\
bit
7
6
5
4
3
2
1
0
0
STX( 02h )
1
Command code (‘ J ‘)
2
Reserve (00h)
3
Reserve (00h)
4
Reserve (00h)
5
Reserve (00h)
6
ETX( 03h )
7
BCCH( high-level )
8
BCCH ( low-level )
a) Answers returned
byte
\
bit
7
6
5
4
3
2
1
0
0
STX( 02h )
1
Reply code (‘ J ‘)
2
Answer code
3
ETX( 03h )
4
BCCH( high-level )
5
BCCH ( low-level )
b) Special condition
- This command is not valid, when system status is Twin REC (32h) or Dubbing (33h).
(The answer code returns “CONDITION ERROR”.)
- This command is valid, when A/B both mecha status data is Stop (42h) or REC Pause (44h).
- The answer code returns “CONDITION ERROR, when A/B both mecha status data is not
Stop (42h) or REC Pause (44h). (Duplicate mode is “OFF”)
- This command is valid, when A mecha status data is Stop (42h) and B mecha status data is
No Tape (41h), Stop (42h) or REC Pause (44h). (Duplicate mode is “MASTER”)
- This command is valid, when A mecha status data is Stop (42h) or REC Pause (44h) and B
mecha status data is No Tape (41h), Stop (42h) or REC Pause (44h). (Duplicate mode is
“SLAVE”)