Ver 1.00
29 page of 30
1.9.19 Speed
This selects tape speed of Twin REC.
byte
\
bit
7
6
5
4
3
2
1
0
0
STX( 02h )
1
Command code (‘ L ‘)
2
Tape speed (*1)
3
Reserve (00h)
4
Reserve (00h)
5
Reserve (00h)
6
ETX( 03h )
7
BCCH( high-level )
8
BCCH ( low-level )
( *1) Tape speed
Code
Tape speed
30h (0)
Normal speed
31h (1)
High speed(x2)
b) Answers
returned
byte
\
bit
7
6
5
4
3
2
1
0
0
STX(02h)
1
Reply code ( ‘ 5 ‘ )
2
Answer code
3
ETX( 03h )
4
BCCH( high-level )
5
BCCH ( low-level )
b) Special condition
- This command is not valid, when system status is Normal (31h) or Dubbing (33h).
(The answer code returns “CONDITION ERROR”.)
- This command is valid, when system status is Twin REC and mecha status data is Stop
(42h) or REC Pause (44h).
- This command is valid only when Duplicate mode is “MASTER” or “SLAVE”.