Software Navigation 

 

Home Screen Apps 

         

     

  

Applications are launched using 

Home Screen

 icons. 

Swipe the Home page to the left for additional icons. 

Up and Back Button 

 

The bottom bar 

Back 

button is generally used to 

navigate to the main level of the current app. If 
accessed from the main level of an app, the button will 
bring up an Exit app dialog box. 

Home Button 

              

 

The bottom bar 

Home 

button is used to navigate to 

the Home screen without closing the app. 

Recents Button 

 

The bottom bar 

Recents 

button is used to as a means 

of displaying recently used apps. Swiping an app to 
the left from the Recents lists will close the app. 

Collapse Button 

 

The bottom bar 

Collapse 

button is used in place of the 

Up and Back button whenever a keyboard is enabled. 
Use this button to dismiss the keyboard. 

     

Top Level Screens 

 

The Application 

Run

Report

 and 

Graph

 screens are 

accessed either by the tabs on the top bar or by 

dragging the screens left or right. 

 

 

Summary of Contents for DS-11 FX

Page 1: ...1 Quick User Manual Rev October 2016 DS 11 FX Spectrophotometer Fluorometer Series...

Page 2: ...aph Screens 8 5 Absorbance Measurement Apps 9 Nucleic Acid Apps 9 Protein Apps 9 Custom Method Apps 9 Additional Apps 9 6 Fluorescence Measurement Apps 10 Standard Curve Based Apps 10 Basic Fluoromete...

Page 3: ...g materials including the protective cover on the screen 2 Plug the unit into a 100 240 VAC 50 60 Hz receptacle using the grounded power supply CUI MPN ETSA120330U P5P SZ Transformer Dest Top 12V 40W...

Page 4: ...ture to perform new Blank measurements Cuvette Measurements 1 Insert a cuvette pre filled with the Blank solution Tap the Blank button 2 Insert a cuvette pre filled with the sample solution Tap the Me...

Page 5: ...only displayed on Report or Graph screens when a DYMO label printer is connected to the instrument The USB Flash Drive Eject icon appears in the bottom notification bar when a drive is detected The so...

Page 6: ...fluorescence apps Basic Measure button is used to make single measurements not being read from a standard curve Fields with Drop Down Menus are indicated by black or white triangles located on the bo...

Page 7: ...tom bar Home button is used to navigate to the Home screen without closing the app Recents Button The bottom bar Recents button is used to as a means of displaying recently used apps Swiping an app to...

Page 8: ...t all data rows Erase highlighted sample records from both the Report and Graph screens using the Delete icon The cleared data will be available using the Data app Tap a sample name and then tap the E...

Page 9: ...recommended when the sample does contain aromatic rings Note For accurate calculated concentrations use the Run screen drop down list to select the optimal sample type for the specific protein measur...

Page 10: ...Quantifluor One dsDNA Fluoro RNA Quant iT RiboGreen Quant iT RNA HS Quant iT RNA BR Qubit RNA HS Qubit RNA BR Quantifluor RNA Quant iT microRNA Qubit microRNA Fluoro ssDNA Quant iT OliGreen Qubit ssD...

Page 11: ...on for all apps each time an app is opened Standard Accounts Any user may add a password protected standard level account Data App This app allows the user to search for past data using either a Quick...

Page 12: ...a network folder Language The language selected determines The DS 11 number format Date Time Network Information and Permissions WiFi and Ethernet Calculator App Three convenient calculators are inclu...

Page 13: ...exported for the Report screen Graphs are not exported as part of the csv file Use the Screen Capture option to export the current graph via email or to save the jpg image to a network folder or a FAT...

Page 14: ...ls are in printed in black and white WiFi and Networked Printers Screen shots as well as selected sample data and graphs may be printed to both WiFi enabled and networked printers DYMO Printers The so...

Page 15: ...measurements Ensure all solutions are homogenous and well mixed prior to sampling Ensure sample concentrations fall within the absorbance limits of the instrument In the case of fluorescence assays e...

Page 16: ...e concentrations in the thin walled assay tubes fall within the limits of the assay or reagent kit for accurate results Follow assay reagent manufacturers recommendations regarding temperature incubat...

Page 17: ...US please contact your local distributor for assistance Warranty All product s and accessories sold by DeNovix Inc are under warranty against manufacturing defects in parts for a 36 month period from...

Reviews: