Page 1: ...This guide has been prepared expressly for the hands on user Always keep it nearby for speedy reference Operator s Guide...

Page 2: ...that comes with Transfer Utility Description about software that transmits data and programs between the handy terminal and computer Ir Transfer Utility C Guide that comes with Ir Transfer Utility C D...

Page 3: ...ning that you should not dis assemble A black circle with a picture inside alerts you to something you MUST do This example shows that you MUST unplug the power cord WARNING Handling the battery cartr...

Page 4: ...injury Avoid dropping the battery cartridge or letting it undergo any shock or impact Doing so could cause the batteries to break generate heat rup ture or burn Only use the dedicated charger CU 7001...

Page 5: ...s not mount beam attenuator and laser radiation emission indicator required by this standard Instead the software controlled Magic keys see Section 2 2 Components and Functions function as them becaus...

Page 6: ...exposed to di rect sunlight Doing so could affect the housing or parts resulting in a fire Avoid using the BHT in extremely humid or dusty areas or where there are drastic temperature changes Moistur...

Page 7: ...r fire If smoke abnormal odors or noises come from the BHT imme diately turn off the power pull out the battery cartridge and contact your nearest dealer Failure to do so could cause smoke or fire Nev...

Page 8: ...sure to put your hand through this strap to prevent you from dropping the BHT accidentally Trigger switch M3 key Press this switch to start bar code reading Optical interface port Used to exchange da...

Page 9: ...signed to the M1 and M2 keys by default respec tively If the SF key is held down left and right arrow keys are assigned to the M1 and M2 keys respectively These keys may be used as an SF key ENT key o...

Page 10: ...n read bar codes at a maximum distance of 40 cm 15 7 from the reading window For details about the scanning conditions refer to the BHT 100QF 100BF User s Manual The bar code reading procedure may dif...

Page 11: ...er of the scanning range indicated by the laser beam When you pull the bar code reading window away from bar codes the actual scanning range will become narrower than the range covered by the laser be...

Page 12: ...sources of radio waves in the 2 4 GHz band Electromagnetic noise from personal computers refrigerators and other home appliances can also interfere with link operation Environmental factors that can a...

Page 13: ...CU 7000 Shield the optical interface from direct sunlight ambient intense lighting inverter driven fluorescent lighting in particular and other potential sources of infrared radiation Sources to watch...

Page 14: ...vating or deactivating the backlight function instead of the initial setting combination of SF and the right hand trigger switch as well as modifying the ON duration of the backlight before the automa...

Page 15: ...r Volume and Touch Screen and Switching the Beeper Vibrator While holding down the M1 key or right hand trigger switch M4 press the PW key The main adjustment screen appears which differs depending up...

Page 16: ...ighlight the desired way s by using the M1 or M2 key while holding down the SF key Adjusting the beeper volume You can adjust the beeper volume to four levels from OFF to MAX 1 Use the 3 key or M1 or...

Page 17: ...t screen press the C key Touch the center of the newly displayed To cancel adjustment and return to the main adjust ment screen press the C key Touch the center of the newly displayed To cancel adjust...

Page 18: ...is not completed normally the screen shown at left will appear where you may choose retry or not If you select 1 Yes and press the ENT key the dis play will return to the top screen of the touch scree...

Page 19: ...en input states Displays when the alphabet input function is activated Displays when the touch screen is ready to accept entry Synchronization state Displays when the BHT is synchro nized with an acce...

Page 20: ...up power source which backs up the memory and calendar clock in the BHT when no battery cartridge is loaded or the voltage level of the battery cartridge drops below the specified level The backup pow...

Page 21: ...nd starts preparation for shut down When the above message is displayed do not remove the battery cartridge If you do so and leave the BHT without a battery cartridge loaded for one hour or more then...

Page 22: ...oss After battery replacement turn the BHT on and check the BHT operation If you will use the BHT more than one time per month Keep the battery cartridge loaded in the BHT If you will not be using the...

Page 23: ...procedure contact your system administra tor The indication 00 01 01 00 00 will vary depending upon the calendar clock state The rechargeable battery cartridge can be recharged hundreds of times but...

Page 24: ...per beep After that it will resume previous regular operation Solution The battery recharge or replacement time will come soon Replace or charge the battery cartridge System Program error Problem A Sy...

Page 25: ...p and then turns itself off Depending upon the battery level the beeper may not sound five times Solution Replace or charge the battery cartridge Calendar clock stopped Problem The calendar clock inte...

Page 26: ...em Program the System Program has received an invalid command code xxxxxxxx Error address If this error occurs the BHT beeps five times for 0 1 second per beep Solution Unload and reload the battery c...

Page 27: ...rogram not selected Problem No user program has been selected as an execution program to be run when the power is turned on If this error occurs the BHT beeps five times for 0 1 second per beep and th...

Page 28: ...rator to be called Problem Any of a hardware related error memory error and execution program error has occurred XXXX Error code If such an error occurs the BHT beeps five times for 0 1 second per bee...

Page 29: ...omes smudged moisten a soft cloth with neutral detergent and wring it out thoroughly Wipe the BHT with the cloth and then go over it again with a dry cloth Dust or dirt accumulating on the clear plate...

Page 30: ...e by hand or stain those terminals Doing so could result in a charging failure When connecting or disconnecting the direct connect interface cable to from the BHT do no plug or unplug at an angle and...

Page 31: ...ly to cause harmful interference in which case the user will be re quired to correct the interference at his own expense NOTE This Class A digital apparatus complies with Canadian ICES 003 Cet apparei...

Page 32: ...LABELING...

Page 33: ...hat the following product Kind of equipment Radio frequency module Type designation Range LAN II 6330 is compliance with the essential requirement of 3 of the R TTE Health and safety requirements purs...

Page 34: ...her intellectual property rights of other s but DENSO WAVE cannot be re sponsible for any patent or other intellectual property right infringement s or violation s which arise from i the use of DENSO...

Page 35: ......

Page 36: ...DENSO WAVE INCORPORATED 4 2 12 Toranomon Minato ku Tokyo Japan 105 0001 http www denso wave com 496487 4091...