[5.3]
Beeper scale test
On the TEST menu, selecting "3: BEEPER" calls up the screen
shown at left and makes the beeper sound at three octaves listed
below.
Upon completion of this test, the BHT automatically returns to the
TEST menu.
To stop this test while in progress, turn the BHT off.
Scale Frequency
(Hz)
do 523 1046 2093 4186
re 587
1174
2349 -
mi 659
1318
2637 -
fa 698
1396
2793 -
sol 783
1567
3135 -
la 880
1760
3520 -
ti 987
1975
3951 -
[5.4] Aging
test
On the TEST menu, selecting "4: AGING" proceeds to the aging test
while showing the current date and time on the LCD. (This test is
intended for personnel which check the BHT in the factory.)
Once this test is selected, the automatic powering-off function
becomes disabled. To terminate this test, press the
C
key to return
to the TEST menu or turn the BHT off.
78