Specifications

[ 1 ] Product Specifications

Power Source

-Europe

230 VAC, 16 VA

-U.S.

120 VAC, 13 VA

-Australia

10 to 18 VDC, 450 mA (on 12 VDC)

Power Consumption

8 VA

Dimensions

112 x 142 x 84 mm

(W) x (L) x (H)

(4.41 x 5.59 x 3.31 inches)

Weight

Approx. 220 g (Approx. 7.76 oz.)

Operating Ambient Temperature

0˚C to 40˚C (32˚F to 104˚F)

Operating Humidity

20% to 80% (with no dew condensation)

[ 2 ] Charging Requirements

Charge current:

Approx. 400 mA

Charge time:

Approx. 6 hours

[ 3 ] Interface

Ethernet interface

IEEE802.3, 10Base-T

Pin No.

Signal

Functions

1

TD+

Send data

2

TD-

Send data

3

RD+

Receive data

4

N.C.

No connection

5

N.C.

6

RD-

Receive data

7

N.C.

No connection

8

N.C.

8

1

Summary of Contents for CU-7011

Page 1: ...User s Manual...

Page 2: ...tion may be reproduced in any form or by any means without permission in writing from the publisher Specifications are subject to change without prior notice All products and company names mentioned i...

Page 3: ...ce Please READ through these operating instructions carefully It will enable you to operate your CU 7011 correctly After you have finished reading the instructions keep this manual handy for speedy re...

Page 4: ...r 3 Components and Functions Chapter 4 CU Status Indication by LED Indicators Chapter 5 Applying Power to the CU 7011 Chapter 6 Connecting to Ethernet Chapter 7 Charging the Rechargeable Battery Cartr...

Page 5: ...ns BHT 7000 User s Manual BHT 7000 User s Manual LAN Support Version BHT 100 Series User s Manuals BHT 100 Series User s Manual LAN Support Version BHT BASIC Programmer s Manual BHT BASIC Programmer s...

Page 6: ...e shows that you MUST unplug the power cord WARNING Handling the battery cartridge Never disassemble or heat the battery car tridge nor put it into fire or water doing so could cause battery rupture o...

Page 7: ...socket and contact your nearest dealer Failure to do so could cause fire or electrical shock If you drop the CU so as to damage its housing immediately unplug the AC adapter from the wall socket and...

Page 8: ...the AC adapter from the wall socket for safety Failure to do so could result in a fire When caring for the CU unplug the AC adapter from the wall socket for safety Failure to do so could result in an...

Page 9: ...resulting from any defect in the software or its documentation or resulting from inability to apply the software or its documenta tion DENSO WAVE INCORPORATED does not assume any product liability ar...

Page 10: ...ators 3 Chapter 5 Applying Power to the CU 7011 4 Chapter 6 Connecting to Ethernet 5 6 1 Setting the Transmission Speed of the CU 7011 5 6 2 Interface Cable Connection 6 6 3 Communication with the Hos...

Page 11: ...7011 BHT Ethernet 10Base T FTP Socket API TCP IP Protocol exchange between optical communication and Ethernet MAC address CU 7011 BHT Optical communication Chapter 2 Functions of the CU 7011 The CU 70...

Page 12: ...th the host computer POWER Power LED green Lights when the power is applied to the CU 7011 Optical interface port Used to exchange data optically with the BHT Ethernet interface port 10Base T Used to...

Page 13: ...the host Flashing slowly 1 ON Updating the CU system program Flashing slowly Flashing 2 Waiting for retry after occurrence of a CU system program updating error Flashing slowly Flashing slowly System...

Page 14: ...wires stop using it and contact your nearest dealer Failure to do so could result in a fire or electrical shock WARNING CAUTION Chapter 5 Applying Power to the CU 7011 Apply power to the CU 7011 via...

Page 15: ...1 upside down 3 Remove the protection sheet of the DIP switch from the CU 7011 4 Set the selectors of the DIP switch as shown below ON OFF 1 2 3 O N ON OFF 1 2 3 O N DIP switch Protection sheet alread...

Page 16: ...f the CU 7011 10Base T 8 pin modular RJ45 ITA ETA category 3 or higher Lock lever Ethernet cable When connecting the modular plug insert it until it snaps into place To disconnect it press the lock le...

Page 17: ...user ID 4 Put the BHT on the CU 7011 BHT CU 7011 Take care not to put the hand strap or get any foreign material between the CU and BHT The BHT may fail to communicate with the host 5 To upload a file...

Page 18: ...y cartridge with a new one Generally it is necessary to replace the battery cartridge after it has undergone approx 300 cycles of charging and discharging operation 1 Plug the AC adapter of the CU 701...

Page 19: ...charging Charging completed On standby Indicator LED on the BHT OFF ON in red ON in green OFF Charging Operation and BHT s Indicator LED The charging time is approx 6 hours if the Charge the battery...

Page 20: ...Updating the CU System Program via the BHT You may update the CU 7011 system program by using the BHT 1 Downloading the CU 7011 system program file Download the CU 7011 system program file to the BHT...

Page 21: ...11 Chapter 10 MAC Address The MAC address of the CU 7011 is printed on the nameplate Nameplate MAC address example...

Page 22: ...nches Weight Approx 220 g Approx 7 76 oz Operating Ambient Temperature 0 C to 40 C 32 F to 104 F Operating Humidity 20 to 80 with no dew condensation 2 Charging Requirements Charge current Approx 400...

Page 23: ...ation in the handling and operating of the CU 7011 Please feel free to send your comments regarding any errors or omissions you may have found or any suggestions you may have for generally improving t...

Reviews: