47
Step 4
Disconnect the old battery (1st one) from the battery board and then remove it
from the holder.
<HS/HSS-G >
Connect a new battery (1st one) to the battery board from which you have
disconnected the old one in Step 4, and then load it into the holder.
<HS/HSS-G>
Step 5
NOTE: Do not disconnect both of the current batteries at the same time.
Doing so will lose the encoder positional data.
Old backup battery
(1st one)
Holder
Battery board
Connector
Battery
board
New backup battery
(1st one)