13
1.4.2
Reference Drawings for Stays that Clamp Wiring and Piping
When mounting a stay that clamps wiring and piping to the robot unit, be sure to secure
it with at least two screws using the four existing internal threads provided in the
underside of the second arm.
Referring to the drawing given below, set up a stay.
Note
:
Maintenance and inspection of the robot unit sometimes requires removing
and installing the covers. Mount the stays for wiring and piping so that they
will not interfere with removal/installation of the covers.
HS/HSS-G series
Internal threads (M3, 6 mm deep)
Reference drawing for a
stay
Second arm
First arm
Internal threads (M3, 6 mm deep)
2nd-axis
arm
1st-axis
arm
Stay
Material: SPCC (t2.0)
Surface treatment: Galvanizing
Viewed from A
Existing internal thread positions