44
3.4
Semiyearly Inspections
3.4.1
Lubrication
Apply the specified grease to the whole Z-axis shaft as shown below every six months.
Lubrication Points and Lubricants (HS/HSS-G series)
No.
Lubrication points
Lubricant type
Lubricant
amount
Remarks
Z-axis shaft
Epinoc AP1
2 to 3 cc
Apply the grease to the whole Z-axis
shaft.
<Example of HS-G>
NOTE:
When applying grease to the dust- & splash-proof type or cleanroom type,
you need to pull up and down the upper and lower bellows on the Z-axis
shaft, respectively.
1
No. 1