67
Items Parameters
Defaults
Refer
to:
Enable
(SQRC and QR Code symbols)
Enable
(SQRC symbol only)
Reading SQRC
Disable
√
Permit scan data transmission only
√
Encryption key mismatch
Transmission prohibited
Back-up permitted
√
Encryption key control
Back-up prohibited
Section 7.7
Enable
Reading iQR Code (Square)
Disable
√
iQR Code (Square),
minimum code number readable
1
iQR Code (Square),
maximum code number readable
1 to 61
61
Enable
Reading iQR Code (Rectangular)
Disable
√
iQR Code (Rectangular),
minimum code number readable
1
iQR Code (Rectangular),
maximum code number readable
1 to 15
15
Section 11.3
Enable
Reading Aztec (Full Range)
Disable
√
Enable
Reading Aztec (Compact)
Disable
√
Section 11.3
(See Note 3.)
Aztec (Full Range),
minimum code number readable
1
Aztec (Full Range),
maximum code number readable
1 to 32
32
Aztec (Compact),
minimum code number readable
1
Aztec (Compact),
maximum code number readable
1 to 4
4
Section 11.3
(Note 3)
Using the QR-coded parameter menu enables or disables scanning of both Full Range and Compact Aztec symbols
at the same time.
: Can be changed only with the configuration software.