64
Codabar (NW-7)
Items Parameters
Defaults
Refer
to:
Reading Enabled (Check digit
:
Disabled)
Reading Enabled (Check digit
:
Enabled, with C/D transmission)
Reading Enabled (Check digit
:
Enabled, without C/D
transmission)
Reading Codabar (NW-7)
Disable
Minimum number of readable digits for
Codabar (NW-7)
4 digits
Maximum number of readable digits for
Codabar (NW-7)
3 to 99 digits
(including start/stop codes)
99 digits
(See Note 1.)
Transmit (a/b/c/d)
Transmit (A/B/C/D)
Transmission of Start/Stop codes
for Codabar (NW-7)
Disable
MOD-16
Check digit calculation method
for Codabar (NW-7)
7-check method
(Note 1) The parameter setting ranges are different from the numbers of digits that the scanner can actually read.
: Can be changed only with the configuration software.
Code 39
Items Parameters
Defaults
Refer
to:
Reading Enabled (Check digit
:
Disabled)
Reading Enabled (Check digit
:
Enabled, with C/D transmission)
Reading Enabled (Check digit
:
Enabled, without C/D
transmission)
Reading Code 39
Disable
Minimum number of readable digits for
Code 39
1 digit
Maximum number of readable digits for
Code 39
1 to 99 digits
(excluding start/stop codes)
99 digits
(See Note 1.)
Enable
Transmission of Start/Stop codes
for Code 39
Disable
Enable
Conversion to FULL ASCII
Disable
(Note 1) The parameter setting ranges are different from the numbers of digits that the scanner can actually read.
: Can be changed only with the configuration software.
Summary of Contents for QK31-R
Page 1: ...2D Code Scanner Fixed type QK31 R QK31 U User s Manual...
Page 88: ...77 Header USB keyboard interface None default STX ETX CR LF CR LF TAB ESC ENTER Right Ctrl...
Page 89: ...78 Header USB keyboard interface...
Page 90: ...79 Terminator USB keyboard interface None STX ETX CR LF CR LF TAB ESC ENTER default Right Ctrl...
Page 107: ...96 Appendix 5 Outer Dimensions Unit mm QK31 R 125 90 85 40 50 51 5 58 50 10 QK31 U...