25
Appendix 1. Specifications
Item
SP1-QUBi
Scanning
spec.
RFID
RF tag
ISO/IEC 1800-63 Type
C (EPC global Class 1 Gen2) compatible
Frequency
See next page
RF Power
See next page
Modulation
PR-ASK
Scanning speed(*1)
700 tags per second MAX.
Scanning distance(*1)
Aprrox. 8m MAX.
Output adjustment
10 – 30dBm
Code
scanner
Readable codes
QR Code (Model 1 and Model 2), MicroQR, SQRC (*2), PDF417,
MicroPDF417, MaxiCode, Data Matrix, and EAN.UCC Composite
symbol
EAN-13/8, UPC-A/E, UPC/EAN with add-on, Interleaved 2 of 5 (ITF),
Standard 2 of 5 (STF), Code 39, Codabar (NW-7), Code 93, Code 128,
GS1-128 (EAN-128), and GS1 DataBar (RSS)
Skew angle
360°
Scanning resolution
0.167 mm (6.6 mils) min. for two-dimensional codes
0.125 mm (4.9 mils) min. for barcodes
Elevation angle (skew)
±50
°
Tilt angle (pitch)
±50
°
Light source
LED (red)
Reading confirmation
Blue LED, and beeper
Interface
Bluetooth
®
Bluetooth
®
Specification Ver. 2.1+EDR compatible
Profile(s) supported
SPP (Serial Port Profile), iAP2
Input power Main power
Li-ion battery(BT-180LA, BT-SP1L)
Internal memory
80,000 RF tags
Operating time (*3)
4 hours(BT-180LA), 8hours(BT-SP1L)
Environmental
conditions
Operating temperature range
-20
°
to 40
°
C(
∗
4)
Charging temperature range
0
°
to 40
°
C(18
°
to 25
°
C
recommended
)
Operating humidity range
5% to 95% RH (
∗
5)
Storage temperature range
-20
°
to 60
°
C
Storage humidity range
5% to 95% PH (
∗
5)
Drop resistance (
∗
6)
30 drops from 1.2m onto concrete(5times on each of 6faces), 1.5m
Protection rating
IP54
Tumble (
∗
6)
1000 drops (0.5m)
Dimensions (W) × (D) × (H)
90 × 174 × 128 mm
Weight
Approx. 400 g (with BT-180LA), Approx. 450 g (with BT-SP1L)
(
∗
1) Function settings may be subject to restrictions in some countries..
(
∗
2) To use SQRC outside of Japan, contact your Denso Wave representative.
(
∗
3) These operating times are reference values measured under room temperature and other conditions set by our company. Actual operating
times depend on working conditions. Conditions set by our company: Power Save Mode 2, RF Tag Continuous Read Mode 1, LOW beeper
level.
(
∗
4) When the product is used at ambient temperatures of -10°C or below, turn on the product and operate briefly at normal room temperature
before taking the product to the worksite; do not turn off.
Due to battery characteristics, operations may be subject to certain limitations, such as significantly decreased operating time, under low
temperature conditions (0°C or lower). If ambient
temperatures are very low, check for normal function before using the product.
.