background image

 

vi 

 

CAUTION

 

Improper handling of the scanner may cause heat generation/fuming,device failure. 
Keep the following precautions in mind when using: 

 

 When disconnecting the AC adapter from the wall socket, hold the AC adapter body not the 

power cable.

 

 

The power cable may be broken, resulting in a burnt AC adapter, electrical shock, or fire. 

 If the interface cable is damaged (e.g., exposed or broken lead wires), stop using it and 

contact your nearest dealer.

 

  Failure to do so could result in a fire or electrical shock. 

 

 During electrical storm activity, always unplug the AC adapter from the wall socket.

 

  Exposure to power surges could result in a damaged scanner or fire. 

 When taking care of the scanner, unplug the AC adapter from the wall socket for safety.

 

  Failure to do so could result in an electrical shock. 

 Do not drop the scanner.

 

  The scanner housing may be broken, creating injuries.

 

  Using the scanner whose housing is broken could result in smoke or fire.

 

  Unplug the AC adapter from the wall socket and contact your nearest dealer. 

 

 

 

 

 

 

Cleaning 

 Cleaning the scanner 

Clean the scanner with a soft, dry cloth. 

 

 

 

 

 

 

 

CAUTION 
(1)  Do NOT use any cleaning agent such as naphtha or alcohol. The housing may be degraded or the sticker or coating could peel 

off. 

(2)  If it is noticeably dusty or dirty, wipe it using a clean cloth soaked with water-diluted detergent (it should be slightly wet) and 

then wipe it with another dry cloth. 

Summary of Contents for UR21-MR-01

Page 1: ...RFID table scanner UR21 MR 01 UR21 MS 01 User s Manual ...

Page 2: ...ial without prior consent is strictly prohibited QBdirect is a registered trademark of DENSO WAVE INCORPORATED Windows is a registered trademark of Microsoft Corporation in the United States and other countries Company names and products are generally the trademark or registered trademark of that company Specifications are subject to change without notice ...

Page 3: ...RS 232C interface used 6 Connecting the scanner to the computer when USB interface used 8 Chapter 4 How to Read RF Tags 10 Chapter 5 RFID Table Scanner Control and Parameter Settings 12 5 1 Read Control 12 5 2 Parameter Settings 12 Chapter 6 Status Check 13 Chapter 7 Upper Level Communication 14 Chapter 8 Troubleshooting 15 Appendix 1 Specifications 16 Radio Wave Specifications 860MHz band 16 Radi...

Page 4: ...l Property Precaution DENSO WAVE INCORPORATED DENSO WAVE takes reasonable precautions to ensure its products do not infringe upon any patent of other intellectual property rights of other s but DENSO WAVE cannot be responsible for any patent or other intellectual property right infringement s or violation s which arise from i the use of DENSO WAVE s product s in connection or in combination with o...

Page 5: ...information for new products Free web information service QBdirect QBdirect Service Contents Information search service FAQ Offers detailed information on each product Download service Offers downloads of the latest system software update modules and sample programs E mail inquiries Allows customers to send product related queries by e mail Please note that these privileges may be subject to chang...

Page 6: ...ose conditions that could cause serious bodily injury or death if the instructions are not followed correctly CAUTION Alerts you to those conditions that could cause minor bodily injury or substantial property damage if the instructions are not followed correctly Meaning of Symbols A triangle with a picture inside alerts you to a warning of danger Here you see the warning for electrical shock A di...

Page 7: ... large current through the scanner resulting in heat or fire as well as damage to the scanner Keep the AC adapter away from water Failure to do so could cause fire or electrical shock Never use the scanner on the line voltage other than the specified level Doing so could cause the scanner to break or burn Do not use the scanner where any inflammable gases may be emitted Doing so could cause fire D...

Page 8: ...r blanket Doing so could cause the unit to heat up inside deforming its housing resulting in a fire Always use the scanner and AC adapter in a well ventilated area Keep the power cable of the AC adapter away from any heating equipment Failure to do so could melt the sheathing resulting in a fire or electrical shock Do not scratch or modify the scanner or its interface cable Do not bend twist pull ...

Page 9: ...e to power surges could result in a damaged scanner or fire When taking care of the scanner unplug the AC adapter from the wall socket for safety Failure to do so could result in an electrical shock Do not drop the scanner The scanner housing may be broken creating injuries Using the scanner whose housing is broken could result in smoke or fire Unplug the AC adapter from the wall socket and contac...

Page 10: ...red Using the DLL supplied by us application programs can easily be built in the computer in a general purpose development environment Visual Studio etc Some of the hardware requirements differ according to the communication system used CAUTION 1 Computer and interface cable are not included in this package they are available from suppliers 2 Two antennas can be connected to the controller Antenna...

Page 11: ... Controller URCT M21 Antenna URAN R2 Cover Cover locking screw Coaxial cable overall length 2000 mm Antenna stay locking screw 4 pcs Safety Precautions UR21 MR 01 Items contained in the package UR21 MS 01 interface RS 232C USB Controller URCT M21 Antenna URAN S1 Cover Cover locking screw Safety Precautions Antenna UR21 MS 01 Safety Precautions Controller Cover Cover locking screw Antenna stay Lock...

Page 12: ...e Chapter 6 Controller side coaxial connector ANT1 Connects to the antenna with the coaxial cable DC jack Accepts the DC plug of the AC adapter RS 232C communication connector Connects to a computer etc via the interface cable Controller side coaxial connector ANT2 USB communication connector Connects to a computer etc via the interface cable ...

Page 13: ...heck for such problems 75 75 4 M4 4 Notes 1 If the plate thickness of the antenna mounting stay is 2 mm t 2 mm it can be secured with the screws L 6 mm included in the package If the plate thickness of the antenna mounting stay is not 2 mm t 2 mm use screws whose length of thread engagement is 3 to 4 mm inside the antenna 2 If you fail to tighten them to recommended torque 0 53 to 0 95 N m they ma...

Page 14: ...ch the antenna connector to the connector on one end of the coaxial cable Push the connector firmly until it is locked 2 Attach the other connector of the coaxial cable to the controller s antenna connector Push the connector firmly until it is locked 3 If the UR21 MR 01 is used in combination with two antennas attach the second antenna s coaxial cable connector to the controller s antenna connect...

Page 15: ...nnect the RS 232C interface cable to the computer Secure the connectors with their screws Attach the connector Lock the connector Note This figure shows an example of a computer The RS 232C interface cable should be connected in accordance with the instruction manual for the computer used Note Run the cable through the cover in advance and then connect it ...

Page 16: ...g position of the controller Fasten the cover to the controller using the screw included in the package recommended torque 0 25 to 0 50 N m Note 1 When removing the connector and DC plug hold the connector If you hold the cable when removing this may cause a broken wire 2 The connector should be attached removed only when absolutely necessary Doing so frequently may result in a loose connection No...

Page 17: ... the controller s USB connector 2 Connect the USB cable to the computer Note This figure shows an example of a computer The RS 232C interface cable should be connected in accordance with the instruction manual for the computer used Note Run the cable through the cover in advance and then connect it ...

Page 18: ...broken wire 2 Do NOT violently pull the cable It may be disconnected 3 The connector should be attached removed only when absolutely necessary Doing so frequently may result in a loose connection 1 2 Fasten the cover to the controller using the screw included in the package recommended torque 0 25 to 0 50 N m Align the protrusions on the cover with the screw holes in accordance with the mounting p...

Page 19: ...ations microwaves etc Keep it as far away from any metal objects or equipment using radio waves Before installing the antenna check for such problems 2 The reading range is based on the center of the antenna 3 If another RFID device is used nearby RF tags may be difficult to read or they could be read at all 4 While the scanner reads a RF tag it should be kept parallel to the antenna where possibl...

Page 20: ... are any metal objects other than the dedicated stay or equipment using radio waves mobile phones amateur radio stations microwaves etc Keep it as far away from any metal objects or equipment using radio waves Before installing the antenna check for such problems 2 The reading range is based on the center of the antenna 3 If another RFID device is used nearby RF tags may be difficult to read or th...

Page 21: ...ite processing Write to Memory Lock or Kill than in read processing 5 2 Parameter Settings Antenna parameter settings can be made with the RFID table scanner For details see DLL Reference Manual or Command Manual Carrier output intensity The carrier output for communicating with RF tags can be adjusted Output enabled frequency If in the region it is possible to select output frequency channels it ...

Page 22: ...mpleted Lit Unlit Unlit Lit Open command executed Antenna port setting made Ready for receiving commands from upper level device Lit Unlit Lit Note 1 Lit Note 1 Transmitting RF carrier wave Lit Unlit Blinking Note 1 Blinking Note 1 Communicating with upper level device Lit Lit Lit Note 1 Lit Note 1 Note 1 The status indicator LED ANT1 ANT2 corresponding to the port enabled by the antenna port sett...

Page 23: ... to the driver Precautions to be taken when installing and using the Active USB COM port driver You must have administrator rights to install the driver This driver does not have a digital signature issued by Microsoft Corporation use Driver Signing Options and Local Policies Security Options to allow unsigned drivers to be installed The USB device can be removed from the PC USB Port during commun...

Page 24: ...rectly or could not be read at all Are there any metal objects or equipment using radio waves around the antenna If so keep them as far away from the antenna as possible Are there any metal objects at near the RF tag attached area If so keep the tag at least 15 cm away from them Is the RF tag or the RF tag attached area is wet If so dry and then retry reading Is the PW LED lit If not make sure tha...

Page 25: ... Australia 918 25 MHz to 925 75 MHz at 500kHz intervals a total of 16 channels Communication frequency for Hong Kong 920 25 MHz to 924 75 MHz at 500kHz intervals a total of 10 channels Communication frequency for Taiwan 922 25 MHz to 927 75 MHz at 500kHz intervals a total of 12 channels Communication frequency for Korea 917 3 MHz to 920 3 MHz at 600kHz intervals a total of 6 channels Communication...

Page 26: ... Communication speed 50 kbps M 4 Precautions to be taken during RFID communication Even in the case of an RF tag conformable to the specifications described above you may experience unstable communication or communication failure To avoid such problems carefully check the operation of the scanner with RF tags intended for use in the actual operating environment Do NOT touch the antenna and its sur...

Page 27: ...rating humidity range 20 to 80 RH see Note 1 Storage temperature range 10 to 60 C Storage humidity range 20 to 80 RH see Note 1 External dimensions Controller 90 108 5 31 mm Antenna for UR21 MR 01 200 200 17 5 mm Antenna for UR21 MS 01 200 200 5 mm Coaxial cable Overall length 2000 mm Weight Controller Approx 130 g Antenna coaxial cable not included Approx 360 g UR21 MR 01 Approx 250 g UR21 MS 01 ...

Page 28: ... in the absence of any object substance that may affect radio waves around the scanner The reading range varies according to RF tag type and surrounding environment It should be checked with RF tags intended for use in the actual installation environment before use Scanning range at normal temperature and humidity When RF tag placed in horizontal position Setting Output Power H reading distance L1...

Page 29: ...bles the write operation Appendix 2 Interface Specifications RS 232C Interface D Sub 9 pin plug type USB interface Communication connector USB MINI B Type Pin No Note 1 Symbol Signal name Input Output Note 2 2 RXD Received data Input 3 TXD Sent data Output 5 SG Signal Ground 7 RTS Request to Send Output 8 CTS Clear to Send Input Pin No Symbol Signal name Input Output see Note 1 Remarks 1 Vbus VBUS...

Page 30: ...RFID table scanner UR21 MR 01 UR21 MS 01 User s Manual Preliminary Edition October 2017 DENSO WAVE INCORPORATED AUTO ID Business Unit Engineering Division ...

Page 31: ...DENSO WAVE INCORPORATED 1 Yoshiike Kusagi Agui cho Chita gun Aichi pref 470 2297 JAPAN http www denso wave com ...