80
Normal Operation of Cooling Fan (VS-G)
3.3 Quarterly
Inspections
3.3.1 Check
Items
Check the items listed in the table below every three months.
Quarterly Inspections Table
No. Check:
Controller
Power
How to check:
Criterion
What to do:
1
Robot base
mounting bolts
OFF Measure
the
tightening
torque with a
torque wrench.
No looseness.
Specified torque:
110
±
22 Nm
Tighten the bolts to
the specified
torque.
2
Cooling fan filters
in the robot
controller
OFF
Visually
No dust or dirt.
Clean the cooling
fan filters. (Refer to
Section 3.3.2.)
3.3.2 Cleaning the Cooling Fan Filters in the Robot Controller
For the cleaning procedures of the air intake filter, refer to the RC7M CONTROLLER
MANUAL, Section 6.4 "Cleaning the Air Intake Filter."