Chapter 9 Vision Manager
153
Note
Projection window
9.2.6.2 Editing a window
The following is the procedure for editing a window.
Operating procedure
1.
Enter the window number in the Target window field to display the settings for the window
specified on the Window settings screen and display the image in the Vision monitor win-
dow.
2.
Adjust the window size.
3.
Press the Register button.
9.2.6.3 Deleting a window
Operating procedure
1.
Enter the number of the window in the Target window field. to display the settings for the
window specified on the Window settings screen.
2.
Press the Delete button.
Rectangular and sector window shapes add an edge detection direction setting.
This parameter specifies the scan direction for edge detection. Set this to 2 (none) if edge detection
is not used. This is the default setting when a window is first created and after a shape change.
Change this setting to match the measurement method.
• Rectangular window
• Sector window
Parameter = 0 (X-axis projection)
Origin
Height
Width
Parameter = 1 (Y-axis projection)
Parameter = 2 (None)
(No projection)
Parameter = 0 (Meridional direction projection)
Parameter = 1 (Circumferential projection)
Parameter = 2 (None)
(No projection)
Summary of Contents for WINCAPS III
Page 1: ...Programming Support Tool WINCAPSIII GUIDE...
Page 18: ...vi CONTENTS...
Page 64: ...46 Chapter 3 Starting Up Shutting Down...
Page 196: ...178 Chapter 10 Appendices...
Page 198: ......