160
Chapter 9 Vision Manager
9.2.8.1 Manually specifying boundaries
Operating procedure
1.
Choose the Histogram radio button to display the Histogram settings screen.
2.
Select the Processing window to display the histogram calculation window.
3.
Press the Calculate button to display the histogram.
4.
Select the Digitization radio button to display the Digitization settings screen.
5.
Specify the two digitization thresholds and check the lines on the histogram.
6.
Press the Apply button.
9.2.8.2 Automatically determining digitization thresholds
Operating procedure
1.
Press the Histogram radio button to display the Histogram settings screen.
2.
Choose the window to process in the Processing window.
3.
Choose the method: calculation with mode method, discriminant analysis, or p-tile thresh-
old calculation.
If your choice is other than p-tile, proceed to step 5.
4.
(For p-tile only) Specify the reference area and target fields.
5.
Press the Measure button to display the resulting boundaries on the histogram and save
them in the two boundary fields of the Digitization settings screen.
6.
Select the Digitization radio button to display the Digitization settings screen.
7.
Press the Apply button
Before digitization
After digitization