Section 4
Electrical and Plumbing Requirements
Sybaritic, Inc.
Dermalife
®
Spa-Oceana™ 2G
System
10
4.2 Plumbing Installation Requirements
NOTE
:
Only a qualified/certified/licensed plumber is authorized to make the plumbing
installation strictly according to all local plumbing installation requirements.
•
The unit’s power supply must be shut off prior to installation and/or any work on the unit.
•
For plumbing installation, the
right hand side panel of the unit
must be carefully removed.
After installation, the side panel
must be reinstalled before
operating the unit.
•
Minimum allowed water
pressure is 1.5 bars (21.75 psi) and maximum allowed water pressure is 4 bars (58 psi).
•
Pressure difference between cold and hot water supply must not exceed 2 bars (29 psi).
•
For normal over-body jet operation, the cold water must be b50 to +59°F (+10 to
+15°C) and the hot water b122 to +140°F (+50 to +60°C).
•
Cold water supplying the steam generator must have measured water hardness below
71ppm USA (<4 PH German); if the water supply is harder, a water softener must be
installed for the steam generator.
•
The water supply for this unit must be mechanically cleaned/filtered. In order to avoid
damage to the unit subparts, nonsoluble, solid elements in the water supply must be less
than 50 microns. In order to guarantee that, it is necessary to install mechanical water filters
(50 micron filtering). Filters must have a flow rate of 2.5 gallons (9.5 liters) per minute.
•
All other water supply characteristics must meet the local drinking water requirements.
•
Water supply connections in capsule are for ½” water inlets and the drain is 40mm.
•
BOTH THE COLD AND HOT WATER SUPPLY MUST HAVE SHUTOFF (OPEN/CLOSE)
VALVES THAT WOULD ENABLE REGULAR, EASY OPENING AND CLOSING OF THE
VALVES.
•
IN ORDER TO AVOID WATER SUPPLY PIPE BURSTS AND/OR FLOODING, THIS UNIT
MUST BE PROTECTED WITH COLD AND HOT WATER SHUTOFF VALVES. SHUTOFF
VALVES ENABLE THE OPERATOR TO CUT OFF THE WATER SUPPLY WHEN THE
UNIT IS NOT BEING OPERATED. THIS UNIT MUST NOT BE CONNECTED TO THE
WATER PRESSURE CONTINUOUSLY; THE WATER SUPPLY MUST BE CUT OFF AT
ALL TIMES WHEN NOT IN USE.
•
½” hot and cold lines should come from the floor or wall to the area where the unit is to be
placed. Connect them to the ½” male connections on the thermostatic mixing valve on the
right side of the unit.
•
Ensure that the water lines are purged of sand and grit prior to final connection to the unit.
•
The capsule’s 1 ½” (40mm) O.D. drain should be spilled directly or indirectly into the
drain/floor sink.
•
Dermalife
®
Spa-Oceana™ 2G has a steam/shower system that utilizes approximately 64 gallons
(240 liters) of water per 30-minute shower session.
•
Assume 40 gallons (150 liters) of this to be hot water.
•
Based upon the expected number of sessions daily, an appropriate hot water supply needs
to be installed.
Summary of Contents for Spa-Oceana 2G
Page 39: ...Section 7 Operation Sybaritic Inc Dermalife Spa Oceana 2G System 33 Hydro Working Charts ...
Page 40: ...Section 7 Operation Sybaritic Inc Dermalife Spa Oceana 2G System 34 ...
Page 42: ...Section 7 Operation Sybaritic Inc Dermalife Spa Oceana 2G System 36 Cleansing ...
Page 43: ...Section 7 Operation Sybaritic Inc Dermalife Spa Oceana 2G System 37 Relaxation ...
Page 44: ...Section 7 Operation Sybaritic Inc Dermalife Spa Oceana 2G System 38 Aquatica ...
Page 45: ...Section 7 Operation Sybaritic Inc Dermalife Spa Oceana 2G System 39 Muscle Care ...
Page 46: ...Section 7 Operation Sybaritic Inc Dermalife Spa Oceana 2G System 40 Smoothing ...
Page 47: ...Section 7 Operation Sybaritic Inc Dermalife Spa Oceana 2G System 41 Escape ...
Page 48: ...Section 7 Operation Sybaritic Inc Dermalife Spa Oceana 2G System 42 Sleep Meditation ...
Page 49: ...Section 7 Operation Sybaritic Inc Dermalife Spa Oceana 2G System 43 Body Wrap ...
Page 50: ...Section 7 Operation Sybaritic Inc Dermalife Spa Oceana 2G System 44 Hot Cold ...
Page 84: ...Owner s Notes ...