DERRICK
®
CORP. - MOTOR DATA SHEET
JFS M:\Motor Docs\Pe-s-250.doc (Maintenance)
U:\Motor PDFs\Pe-s-250.pdf (view/print)
DOC# PE-S-250-03
Wire Code
Power
Black, White & Red
Ground
Green
Thermal Switch
Orange & Blue
1500 RPM
MODEL
:
SGX VIBRATOR - 50 HZ - (EXPLOSION PROOF TERMINAL BLOCK STYLE)
Vibrator Model
SGX-
215/220-50
SGX-
230/240-50
SGX-
380/400-50
SGX-
415-50
SGX-
440-50
SGX-
690-50
Voltage
[Volts]
215/220
230/240
380/400
415 440 690
Phase / Frequency [Hz]
3/50 3/50 3/50 3/50 3/50 3/50
Speed
[RPM]
1500 1500 1500 1500 1500 1500
Rated Horsepower [HP]
2.5 2.5 2.5 2.5 2.5 2.5
Current @ Idle / Full Load
[Amps]
3.6 / 7.1
3.3 / 6.5
2.1 / 4.0
1.9 / 3.8
1.8 / 3.6
1.1 / 2.3
Locked Rotor Current [Amps] /
Locked Rotor Code
28.4 / D
26.0 / D
15.6 / D
15.1 / D
14.2 / D
9.1 / D
Fuse - Non Delay [Amps]
20
20
12
10
10
7.5
Overload
protection
[Amps]
8 7 5 4 4 3.5
Data below is common to all model
SGX-50
vibrators.
Insulation class
F
Ambient temperature
55º C
Operating temperature code
T3C
Maximum temperature rise
46º C by resistance
Duty CONTINUOUS
Thermal switch rating
Pilot Duty 720VA, 110 – 600VAC
Thermal switch type
Normally Closed
Thermal switch temperature
Opens @ 145º C / Closes @ 140º C
Power factor - operations
99.13
Efficiency - running
98%
Service Factor
1.0
NEMA design
TENV
Ingress Protection
IP 56
Weight
415 lbs.-(189 kg) STEEL / 290 lbs.-(132 kg) ALUMINUM
Hazardous location (listed as)
CLASS 1 GROUPS C, D / CLASS 2 GROUPS E, F, G
Listing agency
UL
Hazardous location (listed as)
EExd IIB T3
Listing agency
DEMKO
NOTE:
Derrick
®
vibrators are fixed load devices with no means of altering the loading or power consumption.
Power factor correction capacitors are not recommended for this motor.
03/24/05 – Rev. 3
Page 1 of 1
37.7500
9.5000
Summary of Contents for EX
Page 2: ......
Page 4: ......
Page 6: ......
Page 17: ...EX SGX VIBRATOR MOTORS Figure 2 Motor Cord Connections to Terminal Block 01 May 09 11 ...