background image

www.desatech.com

117191-01A

7

TECHNICAL SERVICE

You may have further questions about your elec-

tric stove. If so, contact DESA Heating Productsʼ 

Technical Service Department at 1-866-672-6040. 

When calling please have your model and serial 

numbers of your heater ready.
You can also visit DESA Heating Productsʼ techni-

cal services web site at 

www.desatech.com

.

REPLACEMENT PARTS

Note:

 Use only original replacement parts. This 

will  protect  your  warranty  coverage  for  parts 

replaced under warranty. 

PARTS UNDER WARRANTY

Contact  authorized  dealers  of  this  product.  If 

they canʼt supply original replacement part(s), 

call DESA Heating Productsʼ Technical Service 

Department at 1-866-672-6040.

When calling DESA Heating Products, have ready
•  your name
•  your address
•  model and serial numbers of your heater 
•  how heater was malfunctioning
•  purchase date
Usually, we will ask you to return the part to the 

factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they canʼt 

supply original replacement part(s), call DESA Heating 

Products at 1-866-672-6040 for referral information.
When calling DESA Heating Products, have ready
•  model number of your heater 
•  the replacement part number

TROUBLESHOOTING

 WARNING: Turn off appliance and let cool before servicing. Only 

a qualified service person should service and repair heater.

POSSIBLE CAUSE

REMEDY

OBSERVED PROBLEM

1. Stove has overheated and safe-

ty devise has cause thermal 

switch to disconnect or home 

circuit breaker has opened

1. Loose wiring

2. Flame motor defective

1. Bulb(s) are burnt out

2. Wiring is loose

1. Bulb(s) are burnt out

1. Flame motor is defective

Stove  turns  off  and  will  not 

turn on

Flame is not moving

Dim or poorly visible flame

Log  set  and/or  ember  is  not 

glowing 

Flame sputters

1. Reset switch by turning main 

power switch off and waiting 5 

minutes then turning it back on

1. Inspect wiring for loose con-

nections

2. Call a qualified service techni-

cian to replace flame motor

1. Inspect bulbs and replace if 

necessary

2. Inspect wiring for loose con-

nections and repair or replace 

if necessary

1. Inspect bulbs and replace if 

necessary

1. Call a qualified service techni-

cian to replace flame motor

Summary of Contents for CGESBM

Page 1: ...ure to follow them could cause a heater malfunction resulting in serious injury and or property damage Save this manual for future reference For more information visit www desatech com MODEL CGESBM ELECTRIC STOVE WITH MANUAL CONTROL SAFETY INFORMATION AND OPERATION MANUAL ...

Page 2: ...o not use this unit for drying wet clothes 5 Do not operate unit if it is damaged or has mal functioned If you suspect the unit is damaged return it to an authorized service facility for examination electrical or mechanical adjust ment or repair 6 Do not use this unit outdoors 7 Do not use or install this unit in areas prone to dampness or where it may come into contact with water This heater is n...

Page 3: ...The unit s power supply cord must be connected to a properly grounded and pro tected 120 volt outlet Always use ground fault protection where required by the electri cal code WARNING Do not operate the unit if it is damaged or has malfunctioned Ifyoususpectthe unit is damaged return the unit to an authorized service facility for examination electrical or me chanical adjustment or repair Model CGES...

Page 4: ...rted and heat will emit the from the vents at the top of the unit To turn off heater turn the temperature dial counter clockwise past number 1 and flip the Heater Switch to OFF position To increase the desired temperature turn the temperature dial clockwise towards Number 8 Todecreasethedesiredtemperature turnthe temperature dial counter clockwise towards number 1 The heater has a built in thermo s...

Page 5: ...Unit 1 Unplug unit from the power supply 2 Remove the four screws in front of the unit that secure the grill to the main frame see Figure 4 3 Four clips hold the front panel to the frame of the unit Lift the front panel upwards until the clips disconnect Remove and place face up on the floor Figure 4 Stove Front Panel Removal Figure 5 Replacing Top Contrasting Bulb Front of Stove CLEANING AND MAINT...

Page 6: ...il it s top edge fits into top drum rack 8 Securetherearcoveroftheunittothemainframe by reattaching screws removed in step 1 9 Replace the log set ember bed 10 Replace the grate to secure the log set 11 Carefully replace front panel by sliding it downward until the clips reconnect 12 Replace the grill to front of unit using screws removed earlier CLEANING FRONT PANEL GLASS WARNING When cleaning uni...

Page 7: ...supplyoriginalreplacementpart s callDESAHeating Products at 1 866 672 6040 for referral information When calling DESA Heating Products have ready model number of your heater the replacement part number TROUBLESHOOTING WARNING Turn off appliance and let cool before servicing Only a qualified service person should service and repair heater POSSIBLE CAUSE REMEDY OBSERVED PROBLEM 1 Stovehasoverheatedan...

Page 8: ... fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY ...

Reviews: