background image

8

104278

VENT-FREE COMPACT FIREPLACE

 CGCF26TPA

INSTALLATION

Note: 

Your Comfort Glow fireplace is de-

signed to be used in zero clearance installations.
Wall or framing material can be placed directly
against any exterior surface of your fireplace,
except where standoff spacers are integrally
attached. If standoff spacers are attached to your
fireplace, these spacers can be placed directly
against wall or framing materials.

Use the dimensions shown for rough open-
ings to create the easiest installation (see
Built-In Fireplace Installation, page 9)

CHECK GAS TYPE

Use only propane/LP gas. If your gas supply
is not propane/LP, do not install fireplace.
Call dealer where you bought fireplace for
proper type fireplace.

INSTALLATION ITEMS

Before installing fireplace, make sure you
have the items listed below.

• external regulator (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• manual shutoff valve *
• test gauge connection *
• ground joint union
• sediment trap
• tee joint
• pipe wrench

*  An A.G.A. design-certified manual shutoff
valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Pur-

 WARNING: A qualified ser-

vice person must install fireplace.
Follow all local codes.

You can recess firebox into the wall. You
can also position fireplace in the optional
cabinet or corner mantels. 

IMPORTANT:

Only use optional cabinet or corner mantels
specified in this manual. Purchase the op-
tional mantel from your dealer (see Acces-
sories
, page 22).

 CAUTION: This fireplace cre-

ates warm air currents. These
currents move heat to wall sur-
faces next to fireplace. Installing
fireplace next to vinyl or cloth
wall coverings or operating fire-
place where impurities (such as
tobacco smoke, aromatic
candles, cleaning fluids, oil or
kerosene lamps, etc.) in the air
exist, may discolor walls.

 WARNING: Never install the

fireplace
• in a bedroom or a bathroom
• in a recreational vehicle
• where curtains, furniture,

clothing, or other flammable
objects are less than 36 inches
from the front, top, or sides of
the fireplace

• as a fireplace insert
• in high traffic areas
• in windy or drafty areas

IMPORTANT: 

Vent-free fireplaces add mois-

ture to the air. Although this is beneficial,
installing fireplace in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Combus-
tion and Ventilation, 
pages 5 through 7.

LOCATING FIREPLACE

 WARNING: Maintain the mini-

mum clearances shown in Fig-
ures 6 and 7. If you can, provide
greater clearances from floor,
ceiling, and joining wall.

Figure 7 - Mounting Clearances As Viewed
From Front of Fireplace Shown with
Optional Mantel

 CAUTION: If you install the

fireplace in a home garage
• fireplace pilot and burner must

be at least 18 inches above floor.

• locate fireplace where moving

vehicle will not hit it.

For convenience and efficiency, install
fireplace

• where there is easy access for operation,

inspection, and service.

• in coldest part of room

An optional blower kit is available from
your dealer. See Accessories, page 22. If
planning to use blower, locate fireplace near
an electrical outlet.

Figure 6 - Mounting Clearances As Viewed
From Front of Fireplace Shown Built In
The Wall

6"

Minimum
From
Sides Of
Fireplace

Left
Side

CEILING

36" Minimum

FLOOR

Right
Side

Top Of
Mantel Can
Be Flush
With Wall

Left
Side

CEILING

Right
Side

36"

Minimum

NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source. If you have a central
heating system, you may run
system’s circulating blower while
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.

chase the optional A.G.A. design-certified
manual shutoff valve from your dealer. See
Accessories, page 22.

Note:

 If desired, purchase a four-sided brass

trim kit for built-in installations. See Acces-
sories, 
page 22.

Summary of Contents for Comfort Glow CGCF26TPA

Page 1: ...his or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s in structions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service ...

Page 2: ...and debris could fall into the control area of fireplace 8 You must operate this fireplace with the fireplace screen in place Make sure fireplace screen is in place before run ning fireplace 9 This fireplace is designed to be smoke less If logs ever appear to smoke turn off fireplace and call a qualified ser vice person Note During initial op eration slight smoking could occur due to log curing an...

Page 3: ...packet 4 Checkfireplaceforanyshippingdamage If fireplace is damaged promptly inform dealer where you bought fireplace PRODUCT FEATURES SAFETY PILOT This fireplace has a pilot with an Oxygen Depletion Sensor Shutoff System ODS The ODS pilot is a required feature for vent freeroomfireplaces TheODS pilotshutsoff the fireplace if there is not enough fresh air PIEZO IGNITION SYSTEM This fireplace has a...

Page 4: ...ided with blower 5 Gently place back log on burner sup port see Figure 2 The log should fit flat against top of burner support Place two 10 one inch long screws through burner support into the log and tighten Place branches on branch support see Figure 2 6 Reattach screen by placing notches in screen frame over shoulder screws and pushing down Figure 2 Assembling Fireplace Back Log Screen Branch B...

Page 5: ...on However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings exposed to the outside atmosphere have a con tinuous water vapor retarder with a rating of one perm 6 x 10 11 kg per pa sec m2 or less with open ings gasketed or sealed and b weather stripping has been added on openable wi...

Page 6: ...liances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr maximum the space can support _________________ Btu Hr actual amount of Btu Hr used Example 51 200 Btu Hr maximum the space can support 56 000 Btu Hr actual amount of Btu Hr used The space in the above...

Page 7: ...ure 4 Ventilation Air from Inside Building Shown with Optional Mantel VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an adjoining unconfined space you must pro vide two permanent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see options 1 and 2 Figure 4 You c...

Page 8: ... bathroom in a recreational vehicle where curtains furniture clothing or other flammable objects are less than 36 inches from the front top or sides of the fireplace as a fireplace insert in high traffic areas in windy or drafty areas IMPORTANT Vent freefireplacesaddmois ture to the air Although this is beneficial installing fireplace in rooms without enough ventilation air may cause mildew to for...

Page 9: ...Wallorframingmaterialcanbeplaced directly against any exterior surface on the rear sides or top of your fireplace Actual Framing Height 26 26 7 8 Front Width 26 3 4 26 7 8 Depth 9 1 2 10 1 2 Bottom 3 4 3 4 Figure 10 Attaching Fireplace to Wall Studs Nails or Wood Screws Nailing Flanges Continued Figure 9 Rough Opening for Installing in Corner WARNING If pre wiring do not connect wiring to any elec...

Page 10: ...Wood Base to Floor 1 3 4 Screw Wood Base Hole for 3 wood screw for attaching fireplace to wooden base Hole for 3 wood screw for attaching fireplace to mantel 4 Assemble brass trim kit See Assem bling Brass Trim page 11 5 Firmly snap brass trim kit on shoulder screws Shoulder screws are located on fireplace cabinet see Figure 12 6 Align brass trim kit for flush fit around opening 7 Use two 3 wood s...

Page 11: ...If sediment trap is not installed or is installed wrong fireplace may not run properly Propane LP Supply Tank Vent Pointing Down External Regulator ATTACHING WOOD BASE TO SOLID FLOOR For attaching base to solid floors concrete or masonry Note Floor anchors and mounting screws areinhardwarepackage Thehardwarepack age is provided with fireplace 1 Drill holes at marked locations using 5 16 drill bit ...

Page 12: ...n nections A flexible gas line is provided to allow accessibility fromthefireplace seeFigure19 The flexible gas supply line con nection to the manual shutoff valve should be accessible Flexible Gas Line from Fireplace Gas Regulator Provided With Fireplace To Fireplace Gas Regulator 4 Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line see Figure 19 Con n...

Page 13: ...me to check for a leak Apply a mixture of liquid soap and water toalljoints Bubblesformingshow a leak Correct all leaks at once CAUTION Make sure external regulator has been installed be tweenpropane LPsupplyandfire place See guidelines under Con necting to Gas Supply page 11 TestPressuresEqualToorLessThan 1 2 PSIG 1 Close manual shutoff valve see Fig ure 20 2 Pressurize supply piping system by ei...

Page 14: ... NOTICE During initial operation of new fireplace burning logs will give off a paper burning smell Orange flame will also be present Open window to vent smell Operate fireplace on HI position to burn off odor This will only last a few hours 4 Wait five 5 minutes to clear out any gas Thensmellforgas includingnear the floor If you smell gas STOP Fol low B in the safety information at the top of colu...

Page 15: ...l cause the thermocouple to cool When the thermo couple cools the fireplace will shut down If pilot flame pattern is incorrect as shown in Figure 25 turn fireplace off see To Turn Off Gas to Appliance see Troubleshooting pages 16 through 18 TO TURN OFF GAS TO APPLIANCE Thethermostaticcontrolusedonthisfire place differs from standard thermostats Standard thermostatssimplyturnonand off the burner Th...

Page 16: ...ged 8 Control valve damaged REMEDY 1 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 2 Reconnect ignitor cable 3 Replace ignitor cable 4 Replace piezo ignitor 5 Replace ignitor 6 Replace ignitor 1 Turn on gas supply or open manual shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob while in PILOT position 4 Continue holding down control knob Repe...

Page 17: ...eated vapors from furniture pol ish wax carpet cleaners etc turn into white powder residue REMEDY 1 Clean burner see Cleaning and Mainte nance page 19 or replace burner orifice 2 Replace burner orifice 3 Contact local propane LP gas company 1 Contact local propane LP gas company 2 Clean burner see Cleaning and Mainte nance page 19 or replace burner orifice 1 Clean burner see Cleaning and Mainte na...

Page 18: ...ment at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Not enough combustion ventilation air OBSERVED PROBLEM Fireplace produces a clicking ticking noise just after burner is lit or shut off Fireplace produces unwanted odors Fireplace shuts off in use ODS operates Gas odor even when control knob is in OFF pos...

Page 19: ...wor gas quality is bad If so contact your local propane LP gas supplier CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount of air to mix with the gas This provides a clean burning flame Keep these holesclearofdust dirt andlint Cleanthese air inlet holes prior to each heating season Blocked air holes will create soot We rec ommend that you c...

Page 20: ...CT FIREPLACE CGCF26TPA 12 1 12 2 ILLUSTRATED PARTS BREAKDOWN CGCF26TPA 17 23 29 32 8 14 36 37 13 7 8 42 33 11 4 17 10 4 7 8 8 30 3 1 2 9 19 6 22 31 21 40 41 38 39 16 15 18 24 28 5 34 26 25 20 35 1 4 35 2 12 24 12 1 25 14 8 3 27 ...

Page 21: ...utlet Tube 1 17 097403 01 Screw Panhead 10 x 1 3 4 2 18 098303 02 Regulator Screw 2 19 104335 01CK Outer Shell Base 1 20 102649 02CJ Branch Support 1 21 099415 09 Gas Regulator 1 22 102875 01 Regulator Bracket 1 23 101381 01 Valve Cover and Piezo 1 24 099387 11 Pilot Tube 1 KEY CGCF26TP NO PART NO DESCRIPTION QTY 25 098271 06 Ignitor Cable 1 26 098251 10 Injector 1 27 102458 01CK Middle Rail 1 28 ...

Page 22: ...lete assembly instructions included Three sided brass trim kit included CORNER MANTEL WITH BUILT IN HEARTH BASE Unfinished Birch GMC20U Walnut Finished Birch GMC19F Forusewithfireplace Space savingmantel andhearthbasecornerdesignfeaturesclean classic lines Available in a walnut finish or an unfinished hardwood ready to stain or paint Complete assembly instructions in cluded Three sided brass trim ...

Page 23: ...se Parts Centrals are privately owned businesses They have agreed to support our customer s needs by providing original replacement parts and accessories Dayton Hardware P O Box 275 North Dayton Station Dayton OH 45404 0275 All States 937 258 3721 1 800 762 3426 Parts Department Halco Enterprises 208 Carter Drive Unit 21 West Chester PA 19382 4500 610 430 7717 1 800 368 0803 Parts Department LaPor...

Page 24: ...e or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITSTHEDURATIONOFANYANDA...

Reviews: