8
101697
OPERATION
WITHOUT
THERMOSTAT
To Stop Heater
Press
(OFF) button.
Continued
OFF Button
To Restart Heater
Repeat steps under To Start Heater, page 7.
!
Review and understand the warnings in the Safety
Information Section. They are needed to safely operate this
heater. Follow all local codes when using this heater.
OPERATION
WITH
THERMOSTAT
WARNING
To Start Heater (with thermostat operation)
1. Follow all ventilation and safety information.
2. Fill fuel tank with kerosene or No. 1 fuel oil.
3. Attach fuel cap.
4. Plug power cord of heater into three-prong, grounded extension cord. Exten-
sion cord must be at least six feet long.
Extension Cord Wire Size Requirements
6 to 10 feet long, use 18 AWG rated cord
11 to 100 feet long, use 16 AWG rated cord
101 to 200 feet long, use 14 AWG rated cord
5. Plug extension cord into standard 120 volt/60 hertz, three-hole, grounded
outlet. Heater will display ambient temperature and “OFF” (see Figure 6, page
7). If not, check status of display and refer to Troubleshooting, pages 11 and 12.
6. Press
button until display flashes. Release
button. Heater will flash the
current thermostat set temperature (F˚) for 10 seconds. Press and hold
button to increase thermostat setting or
button to decrease thermostat
setting. Display will automatically advance to next screen 4 seconds after the
last adjustment.
Figure 8 - Adjusting Thermostat
Figure 7 - OFF Button Location