106179-01E
6
For more information, visit www.desatech.com
For more information, visit www.desatech.com
1.
For Model TC100VR, store propane tank(s) in safe manner.
Refer to Chapter 5 of Standard for Storage and Handling of
Liquefied Petroleum Gases, ANSI/NFPA 58 and/or CAN/CGA
B149.2. Follow all local codes. Always store propane tanks
outdoors.
2.
Place plastic cover caps over brass fittings on inlet connector
and hose/regulator assembly.
3.
Store in a dry, clean, and safe place.
STORAGE
CAUTION: Disconnect heater from propane sup-
ply tank(s) for Model TC100VR.
MAINTENANCE
WARNING: Never attempt to service heater while
it is connected to gas supply, operating, or hot.
Severe burns can occur.
1.
Keep heater clean.
2.
Inspect heater before each use. Check connections for leaks.
Apply mixture of liquid soap and water to connections. Bubbles
forming show a leak that must be corrected. Correct all leaks
at once.
3.
Inspect hose/regulator assembly, if used, before each use. If
hose is highly worn or cut, replace.
4.
Have heater inspected yearly by a qualified service person.
CAUTION: Running heater below specified input
rating may cause flashback. During flashback, the
burner flame is mostly yellow. The flame will burn
inside the burner tube, causing a roaring noise. If
flashback occurs, turn heater off. After burner tube
cools, restart the heater.
OPERATION
Continued
OPERATION
STORAGE
MAINTENANCE
SPECIFICATIONS
SPECIFICATIONS
PROPANE MODEL TC100VR
Rating(Btu/Hr)
LOW .......................................... 40,000
MED .......................................... 60,000
HIGH ......................................... 100,000
Fuel ............................................... Propane Vapor Only
Fuel Consumption
Gallons/Hour ........................... .44 Minimum, 1.1 Maximum
Pounds/Hour ........................... 1.86 Minimum, 4.6 Maximum
Supply Pressure (To Regulator)
Maximum ................................ 200 psi
Minimum, for
input adjustment .................. 20 psi
Manifold Pressure ....................... Low-25.6" w.c., High-13.3" w.c.
Ignitor Gap .................................. .15"
Shipping Weight (Pounds) ......... 35
Weight (Pounds)
Heater Weight ......................... 30
Shipping Weight ..................... 35
Size - L x W x H (Inches)
Heater ...................................... 18 x 18 x 34
Carton ...................................... 21.5 x 21.5 x 35
NATURAL GAS MODEL TC100VRNG
Rating(Btu/Hr)
LOW ....................................... 50,000
MED ........................................ 70,000
HIGH ...................................... 100,000
Fuel ............................................. Natural Gas Only
Fuel Consumption
Cubic Ft/Hr ............................. 48 Minimum, 100 Maximum
Supply Pressure (To Regulator)
Maximum ................................ 14 inches w.c.
Minimum, for
input adjustment .................. 6 inches w.c.
Manifold Pressure ....................... Low-3.2" w.c., High-2.8" w.c.
Ignitor Gap .................................. .15"
Shipping Weight (Pounds) ......... 35
Weight (Pounds)
Heater Weight ......................... 30
Shipping Weight ..................... 35
Size - L x W x H (Inches)
Heater ...................................... 18 x 18 x 34
Carton ...................................... 21.5 x 21.5 x 35
TO STOP HEATER
1.
Tightly close gas supply valve. Allow heater to burn remain-
ing fuel in hose.
2.
Shut off burner. Do this by pushing in the control knob and
turning clockwise to the OFF position.
TO RESTART HEATER
1.
Wait five minutes after stopping heater.
2.
Restart heater by following steps under To Start Heater on
page 5.