www.desatech.com
124183-01B
14
GAS SHUTOFF
VALVE OPERATION
Flame Adjustment
Adjust the flame ON/OFF by turning gas shut
-
off valve counterclockwise
to open or
clockwise
to close, as necessary.
Shutting Off Appliance
Turn gas shutoff valve clockwise
to
OFF position.
CURING
LOGS
During the 2-3 hour appliance break-in period,
you may detect an odor from the appliance
as various paints and compounds used in
manufacturing of this log set cure. This is a
normal and temporary situation that is not
cause for alarm. However, you may want to
provide extra ventilation to the room during
this time.
To ensure proper curing of the logs:
• Ignite a 2" flame and maintain it for 1
hour.
• Burn logs in consecutive 1 hour periods
raising the flame an additional 2" to full
flame height for a total of three hours.
OPERATING
INSTRUCTIONS
FOR GA9050A-1
Note: Operation instructions for GA9050A-1
Remote Ready Valve/Pilot Kit will be included
with the kit.
1. STOP! Read the safety information,
column 1.
2. Make sure equipment shutoff valve is fully
open.
3. Press in and turn control knob clockwise
to the OFF position.
4. Wait five (5) minutes to clear out any gas.
Then smell for gas around log set and
near floor. If you smell gas, STOP! Refer
to the
National Fuel Gas Codes, ANSI
Z233.1/NFPA 54, Air for Combustion and
Ventilation
. If you don’t smell gas, go to
the next step.
5. Turn control knob counterclockwise
to the PILOT position and press
in. Keep control knob pressed in for five
(5) seconds.
OPERATION
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: Keep flue open
when operating unit.
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per
-
sonal injury or loss of life.
BEFORE LIGhTING smell all around the ap
-
pliance area for gas. Be sure to smell next
to the floor because some gas is heavier
than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier,
call the fire department.
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information,
above.
2. Turn gas shutoff valve to OFF.
3. Wait five (5) minutes to clear out any gas.
If you then smell gas STOP! Follow the
safety information, above. If you don't
smell gas, go on to the next step.
4. Light a match and lay it on top of pan
material about 2" from end of supply side
of pan
5. Slowly turn gas shutoff valve ON until
burner ignites. If burner doesn’t ignite
within 10 seconds with match burning,
turn shutoff valve OFF and repeat steps
1 through 4 again.