VENTING INSTALLATION

Continued

14 

3

/

8

" Min.

(365 mm)

30" Min.

(762 mm)

1" Min.

(25 mm)

1" Min.

(25 mm)

1" Min.

(25 mm)

Opening "A"

Pitch

Slope Opening "A" 

Max. 

Used Flashing

Model No. 

Flat

15"

V6F-8DM

0-6/12

26.6°

16 

1

/

8

"

V6F-8DM

6/12-

12/12

45.0°

20 

3

/

8

"

V12F-8DM

FLASHING INSTALLATION (V6F-8DM 
OR V12F-8DM)

Determine the flashing to be used with the roof 

opening chart. Slide flashing over pipe until base 

is flat against roof. Replace as many shingles as 

needed to cover exposed area and flashing base. 

Secure in position by nailing through shingles 

(see  Figure  13).  DO  NOT  NAIL THROUGH 

FLASHING CONE.

Installing Flashing on a Metal Roof

When installing the flashing on a metal roof, it is 

required that putty tape be used between the flashing 

and the roof. The flashing must be secured to the roof 

using #8 x 3/4" screws and then sealed with roof coat-

ing to prevent leakage through the screw holes. A roof 

coating must also be applied around the perimeter of 

the flashing to provide a proper seal.

Figure 12 - Roof Opening Measurements

Nail Only 
Outer 
Perimeter 
of Flashing

Storm Collar

Flashing
Cone

Underlap Shingles 
at Bottom

Overlap 
Shingles Top 
and Sides Only

Figure 13 - Flashing Installation

Storm Collar Installation (SC1 or SC2)

Place storm collar over pipe and slide down until 

it is snug against the open edge of the flashing (see 

Figure 14). Use SC1 for all round terminations and 

SC2 for all terminations with slip sections. Apply 

waterproof caulk around the perimeter of the collar 

to provide a proper seal.

Figure 14 - Storm Collar

Chimney 
Pipe

Waterproof 
Caulk

Storm 
Collar

Flashing

Terminations/Spark Arrestor

The fireplace system must be terminated with the 

listed round top or chase terminations. In any case, 

refer to the installation instructions supplied with 

the termination. The termination approved for this 

fireplace are the RT-8DM and RTL-8DM that can 

be used for flashing or chase and ET-8DM, ETO-

8DM, ETL-8DM and ETLO-8DM for chase style 

termination only. Figure 15 shows an RTL-8DM 

round top termination.

 CAUTION: Do not seal open-

ings on the rooftop flashing. Fol-

low the installation instructions 

provided  with  the  termination 

being used.

Attach Bracket 
Tabs to 
Outer Pipe 
(3 Places) 
Secure with 
Screws

RTL-8D

Level of 
Flue Gas 
Outlet

Caulk

Collar

Flashing

Underlap 
Shingles 
Bottom Only

Figure 15 - Termination

Overlap 
Shingles Top 
and Sides

Summary of Contents for VS42 Series

Page 1: ...g approved to ANS Z21 60 Z21 84 or RGA 2 72 standards or for use with a vent free gas log heater approved toANS Z21 11 2 standard A DESA hood must be installed when using a vent free log heater see Accessories page 16 This wood burning fireplace complies with UL127 CAN ULS S610 M87 standard as a FACTORY BUILT APPLIANCE FOR CANADA The authority having jurisdiction such as the municipal building depa...

Page 2: ...f any component part not manufac tured or approved by DESAin combination with a DESA fireplace system Proper installation is the most important step in ensuring safe and continuous operation of the fireplace Consult the local building codes as to the particular requirements concerned with the installation of all factory built fireplaces WARNING Do not install a fireplaceinsertinthisboxunless the manuf...

Page 3: ...NOT LESS THAN 12 1 AIRSPACE TO COMBUSTIBLE COMBUSTIBLE WALL BOARD 0 TO MATERIAL NO COMBUSTIBLE MATERIAL ON FACE SIDEWALL TERMINATION SQUARE CHASE TOP GAS LINE KNOCK OUT AIR KIT KNOCK OUTS ROUND TOP TERMINATION GAS LINE KNOCK OUTS ELECTRICAL OUTLET LEFT SIDE RIGHT SIDE 8 125 12 625 14 25 45 25 41 48 42 24 8 39 16 25 29 5 2 5 10 625 1 12 2 5 8 125 6 75 10 625 12 25 48 0 625 36 22 5 ...

Page 4: ...inimum Maximum Chimney Height for Outdoor Installation The minimum height of the chimney measured from the base of the fireplace to the flue gas outlet of the termination is 8 feet minimum of 4 feet of chimney pipe sections required for outdoor installation FRAMING 1 Frame the opening for the fireplace using the dimensions shown in Figures 1 and 2 2 If the fireplace is to be installed directly on carp...

Page 5: ...tension from shifting and seal gap between the fireplace frame and hearth extension with a non combustible material see Figure 3 WARNING Hearthextension is to be installed only as shown in Figure 3 FIREPLACE INSTALLATION Continued Figure 3 Hearth Extension Seal Gap Fireplace Front Ember Protector Fireplace Front Raised Hearth Fireplace Front Elevated Ember Protector Ember Protector Seal Gap Hearth ...

Page 6: ...ed end up Press down on each pipe section until the lances securely engage the hem on the fire placestarter Thewirewillassuretheproperspacing between the inner and outer pipe sections VENTING INSTALLATION OPTIONAL OUTSIDE AIR KIT MODEL AK4 AK4F The installation of an outside air kit should be per formed during the rough framing of the fireplace due to the nature of it s location Outside combus tion ...

Page 7: ...pipe between supports return elbow or 12S 8DM is 6 of angle run Maximum of two 6 angle run sections per chimney system see Figure 7 4 All pipe connections between the offset and return must be secured with two screws on the outer pipe only see Figure 9 page 8 Do not penetrate the inner stainless OFFSET RISE CHIMNEY LENGTH A B 48 36 24 18 12 4 3 8 16 3 8 ELBOW SET ONLY 9 3 4 25 1 2 1 12 3 4 30 3 4 ...

Page 8: ...of 8 PENETRATING THE ROOF To maintain a 1 clearance to the pipe on a roof with a pitch a rectangular opening must be cut 1 Determine the center point through which the pipe will penetrate the roof 2 Determine the center point of the roof Pitch is the distance the roof drops over a given span usually 12 A 6 12 pitch means that the roof drops 6 for each 12 one measure horizontally down from the roof...

Page 9: ...hing Cone Underlap Shingles at Bottom Overlap Shingles Top and Sides Only Figure 13 Flashing Installation Storm Collar Installation SC1 or SC2 Place storm collar over pipe and slide down until it is snug against the open edge of the flashing see Figure 14 Use SC1 for all round terminations and SC2 for all terminations with slip sections Apply waterproof caulk around the perimeter of the collar to p...

Page 10: ...re 16 Note If a decorative shroud is to be installed contact the manufacturer for specifications 10 FOOT RULE All flue gas outlet chimney terminations must extend a minimum of 3 feet in height above the highest point where it passes through the roof and must be at least 2 feet above the highest point of the roof that is within a horizontal distance of 10 feet see Figure 17 24 Min 24 Min 18 Min Typ F...

Page 11: ...add height Provide sufficient gas line into fireplace chamber for fitting connection see Figure 20 page 12 Note Secure incoming gas line to wood framing to provide rigidity for threaded end Figure 19 Gas Line Knockout Side Firebrick Finished Side Refractory Knockout Plug Outside of Fireplace Gas Line Conduit Insulation Gas Conduit Cover 1 2 Dowel 4 Repack insulation around gas line and into sleeve op...

Page 12: ...in accordance with the National Fuel Gas Code ANSI 7223NFPA 54 latest edition Seal Opening with Refractory Cement Outside of Fireplace Gas Line Conduit Repack Insulation Incoming 1 2 Black Iron Pipe Side Firebrick Finished Side Provide Enough Threaded End for Fitting Connection Figure 20 Gas Line Installation WARNING Toavoidtheriskof damagingthefireplacematerials andincreasingtheriskofspread ingafir...

Page 13: ...for the purpose of installing a vented or vent free decorative gas appliance incorporating an automatic shutoff de viceandcomplyingwiththeStandardforDecorative GasAppliances for Installation in Vented Fireplaces ANSI Z21 60 or American Gas Association draft re quirementsforGasFiredLogLightersforWoodBurn ing Fireplaces Draft NO 4 dated August 1993 OPERATION AND MAINTENANCE GUIDELINES Continued If y...

Page 14: ...11099 01C 14 ILLUSTRATED PARTS BREAKDOWN WOODBURNING FIREPLACE MODELS S42 S42H S42R S42RH VS42 1 AND VS42H 1 9 26 16 33 27 16 27 4 32 34 19 12 25 20 30 17 8 1 5 21 2 35 18 11 14 3 13 22 10 6 31 7 37 38 36 28 29 24 23 15 ...

Page 15: ...Pivot Clip 2 34 20090 Spring Clip 2 35 20280 Top Spacer 4 36 21171 Conduit Plate Cover 4 37 21379 Gas Conduit 2 38 21380 Gas Conduit 2 PARTS AVAILABLE NOT SHOWN 106625 01 Home Owner s Guide 1 Not a field replaceable part KEY NO PART NO DESCRIPTION QTY 9 107812 03 Left Refractory Textured White Brick 1 108169 03 Left Refractory Textured White Herringbone Brick 1 107812 02 Left Refractory Textured Re...

Page 16: ... 30 OFFSET AND RETURN ANTI DRAFT SHIELD ROUND TOP TERMINATION ONLY 30E 8DM STORM COLLAR ROOF FLASHING BI FOLD GLASS DOOR 0 TO 6 12 PITCH V6F 8DM 6 12 TO 12 12 PITCH V12F 8DM ANTIQUE BRASS FINISH GA6053 POLISHED BRASS FINISH GA6052 BLACK PAINTED FINISH GA6050 BDO42 BLACK FINISH BDO42B BRUSHED BRASS FINISH BDO42P PLATINUM FINISH ADJUSTABLE HOOD REQUIRED WHEN INSTALLING A VENT FREE GAS LOG IN THIS FI...

Page 17: ...______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _______________________________________...

Page 18: ...______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _______________________________________...

Page 19: ...______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _______________________________________...

Page 20: ...2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 www desatech com NOT A UPC 111099 01 Rev C 09 05 111099 01 ...

Reviews: