background image

MODEL 268A-1

WARRANTY

Monroe Electronics, Inc., warrants to the Owners, this
instrument to be free from defects in material and
workmanship for a period of two years after shipment
from the factory.  This warranty is applicable to the
original purchaser only.

Liability under this warranty is limited to service,
adjustment or replacement of defective parts (other
than tubes, fuses or batteries) on any instrument or
sub-assembly returned to the factory for this purpose,
transportation prepaid.

This warranty does not apply to instruments or sub-
assemblies subjected to abuse, abnormal operating
conditions, or unauthorized repair or modification.
Since Monroe Electronics, Inc. has no control over
conditions of use, no warranty is made or implied as to
the suitability of our product for the customer's
intended use.

THIS WARRANTY SET FORTH IN THIS ARTICLE IS
EXCLUSIVE AND IN LIEU OF ALL OTHER
WARRANTIES AND REPRESENTATIONS, EXPRESS,
IMPLIED OR STATUTORY INCLUDING BUT NOT
LIMITED TO THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS.  Except for
obligations expressly undertaken by Monroe
Electronics, in this Warranty, Owner hereby waives and
releases all rights, claims and remedies with respect to
any and all guarantees, express, implied, or statutory
(including without limitation, the implied warranties of
merchant-ability and fitness), and including but without
being limited to any obligation of Monroe Electronics
with respect to incidental or consequential damages, or
damages for loss of use.  No agreement or
understanding varying or extending the warranty will be
binding upon Monroe Electronics unless in writing
signed by a duly authorized representative of Monroe
Electronics.  

In the event of a breach of the foregoing warranty, the
liability of Monroe Electronics shall be limited to
repairing or replacing the non-conforming goods and/or
defective work, and in accor-dance with the foregoing,
Monroe Electronics shall not be liable for any other
damages, either direct or consequential.

RETURN POLICIES AND PROCEDURES

FACTORY REPAIR:

Return authorization is required for factory repair work.
Material being returned to the factory for repair must
have a Return Material Authorization number.  To
obtain an RMA number, call 585-765-2254 and ask for
Customer Service.

Material returned to the factory for warranty repair
must be accompanied by a copy of a dated invoice or
bill of sale, which serves as a proof of purchase for the
material.

Repairs will be returned promptly.  Repairs are
normally returned to the customer by UPS within ten
working days after receipt by Monroe Electronics, Inc.
Return (to the customer) UPS charges will be paid by
Monroe Electronics on warranty work.  Return (to the
customer) UPS charges will be prepaid and added to
invoice for out-of-warranty repair work.

EXPEDITED FACTORY REPAIR:

All material returned to the factory by air or by an
overnight service will be expedited.  Expedit-ed factory
repairs will be returned to the customer by the same
mode of transportation by which the material was
returned to the factory for repair (i.e., material returned
to the factory by an overnight service will be returned
to the customer by an overnight service).
NOTE: Return (to the customer) transportation
expenses for expedited factory repairs will always be
at the expense of the customer despite the warranty
status of the equipment.

FACTORY REPAIRS TO MODIFIED EQUIPMENT:

Material returned to the factory for repair that has been
modified will be not tested unless the nature and
purpose of the modification is understood by us and
does not render the equipment untestable at our repair
facility.  We will reserve the right to deny service to any
modified equipment returned to the factory for repair
regardless of the warranty status of the equipment.

MONROE ELECTRONICS, INC.

100 HOUSEL AVENUE

LYNDONVILLE, NEW YORK 14098

PHONE  (716) 765-2254  (800) 821-6001

FAX (716) 765-9330

Summary of Contents for 50555

Page 1: ...7 8178 Fax 909 627 7449 DESCO EMIT EAST 90 Hudson Road Canton MA 02021 1407 781 821 8370 Fax 781 575 0172 Web Site DescoEMIT com TB 6521 02 07 Page 1 of 7 50555 OPERATOR S MANUAL CHARGED PLATE ANALYZER Made in America 2007 DESCO INDUSTRIES INC Employee Owned ...

Page 2: ...or defective work and in accor dance with the foregoing Monroe Electronics shall not be liable for any other damages either direct or consequential RETURN POLICIES AND PROCEDURES FACTORY REPAIR Return authorization is required for factory repair work Material being returned to the factory for repair must have a Return Material Authorization number To obtain an RMA number call 585 765 2254 and ask ...

Page 3: ...Specifications Page 1 Section 2 General Information Page 2 Section 3 Operation Page 4 Section 4 Maintenance Page 6 APPENDIX I Variable Timer Trip Point Option Page 7 Copyright 1998 Monroe Electronics Inc Printed in USA P N 0340097 ...

Page 4: ...lease the two over center latches near the rear of the unit and lift up at the rear of the top section A 20 threaded receptacle is provided inside of the top section for convenient tripod mounting Two foldout legs are provided underneath the bottom of the control unit to elevate the front of the cabinet to permit easy viewing of the meters Switches on the front panel are alternate action push push...

Page 5: ...ource and press on the power switch to apply instrument power The displays will indicate that power is on 2 Select a polarity For discussion purposes we will select positive Press the POLARITY pushbutton in to lock 3 Select a range We will use 5kV as an example Release the 5kV 2kV pushbutton under the PLATE VOLTAGE meter 4 Select NORMAL mode by releasing the NORM PK pushbutton under the meter 5 Se...

Page 6: ...leaning of the case and occasional field meter zero adjustment Further repairs and adjustment require special equipment and are beyond the scope of this manual Factory service is advised CLEANING INSULATORS The insulating standoffs supporting the measuring plate are specifically designed to minimize the effects due to contamination of their outer surfaces Leakage paths created by the skin oils in ...

Page 7: ...t upgrade to the basic Model 268A 1 VARIABLE TIMER OPTION OPERATING INSTRUCTIONS 1 Power unit on 2 Select either 5kV or 2kV plate voltage level measuring range 3 Make sure NORM PEAK button is in NORM position not depressed 4 Set timer STOP LEVEL turn pot to desired plate voltage stop level 0 to 1000 volts 5 Press VARIABLE on TIMER LIMIT switch 6 Select 5kV or 1kV timer start level on TIMER LIMIT s...