TB-6529
Page 3 of 9
Figure 3. Area of optimum charge
neutralization for 50607 and 50609
The C/E series solves this problem.
When the emitters need to be
cleaned, the cassettes are easily
removed from the unit and taken to
another area to be cleaned. This
takes the dirt away from the
workstation and product. To
eliminate downtime, a spare set of
clean emitter cassettes can be
dropped in. The others can be
cleaned when convenient. This
concept is so unique, that we have
been awarded a patent on it.
Features
• Removable emitter cassettes
allow you to minimize
contamination of the work area.
• Closed-loop feedback electronic
balance system continuously
monitors output for optimal
performance.
• I/O port allows auto- calibration
and remote status monitoring.
• Sealed plenum chamber around
each fan minimizes contamination.
• Non-volatile adjustments for
balance and fan speed are
maintained in the absence of
power.
• Lockout key with distinctive
front panel indicator prevents
unauthorized adjustment.
• Balance is individually
adjustable at each fan zone.
• Flashing front panel signal
indicates when cleaning is
needed.
• IEC input and output connectors
allow daisy-chaining of up to 2
units.
• Stainless steel and powder-coated
aluminum construction for
durability and long life.
Specifications
Input Power:
120VAC, 250mA, 24" model
120VAC, 400mA, 48" model
220VAC, 250mA, 24" model
220VAC, 400mA, 48" model
IEC Outlet:
Allows a second unit to be
daisy-chained
Fuse:
5x20mm 3 amp time lag
Air Flow:
80-170 CFM, 24" model
160-340 CFM, 48" model
Emitters:
100% Tungsten, replaceable
Ionization Type:
Steady-state DC
Balance:
0±10 volts at set-up at 24"
above charged plate analyzer
Weight:
6.2 lbs. (24" model)
11.1 lbs. (48" model)
Size:
2" x 6" x 24"
2" x 6" x 48"
Mounting:
(2) ¼" mounting holes each end
Installation
The Desco EMIT’s C/E ionizer is
designed to mount above the work
area, providing even coverage
without using valuable work surface
area. Mounting is a matter of
personal preference, and may be
accomplished with brackets attached
to a shelf, or the unit may be
suspended by chain. Whatever
method is used, care should be taken
to insure that the mounting is secure
and capable of supporting the weight
of the unit. The power cord should
be supported as well to provide
protection against any hazard to the
operator.
“S” hooks are provided with each
unit to facilitate mounting using the
chain suspension method. The ideal
mounting height is 24" above the
work surface, although the ionizer
may be located slightly higher or
lower if required. For maximum
performance, care should be taken to
insure that the intake grills for the
fans are not obstructed.
Turn the power key switch to the
"OFF" position. Plug the IEC end
of the cord into the ionizer and the
other end into a properly wired
outlet. We recommend that the
outlet used by the ionizer be tested
before use and periodically checked
for correct wiring and a good solid
ground. The C/E ionizer depends on
a good ground for proper balancing.
24 IN.
24 IN.
60 IN.
OPTIMUM
PERFORMANCE ZONE
© 2007 DESCO INDUSTRIES INC.
Employee Owned