TB-6545
Page 2 of 2
NOTE: The AC power cord MUST be disconnected before
the unit is disassembled for maintenance. The emitter
electrodes should be cleaned using the alcohol cleaners
included or a swab wet with Isopropyl alcohol. First, turn
the unit OFF and unplug the power cord. Then remove the
back cover by disengaging the 4 screws on back. After
cleaning the emitter electrodes, reattach the back cover
using the 4 screws. Plug in the power cord and turn the
unit back ON.
The emitter electrodes should not require replacement
during the life of the unit with normal handling.
Replacement emitter electrodes can be ordered if
necessary.
Best practice would be to verify the balance of the unit with
a charge plate monitor after cleaning.
Neutralization (Decay) Times
The comparative efficiency of benchtop ionizers is
determined by a standard test published by the ESD
Association: Standard S3.1. Typical positive and negative
decay times (from 1000 volts to 100 volts) measured using
this standard are shown below. The performance of the
ionizer was measured with the unit positioned as shown,
with the fan speed on high, and without a filter.
Figure 2. Neutralization (Decay) Times
Note: Reference ESD STM 3.1-2000. The distance from
the 50680/50681 to the charge plate is 18". (Readings are
typical and taken at maximum fan speed.)
Specifications
Air Flow
Three speed fans (125fpm -250fpm; 50-100cfm).
Balance
±10 volt, typical; ±20 volts maximum.
(Temperature range: 65°F to 80°F, R.H.: 15% to 65%)
Chassis
White powder coated steel housing.
Dimensions
3.5" height x 6.5" width x 37" length.
Emitter Points
.050" diameter pure tungsten for improved mechanical
strength and ionization stability.
Fuse
400mA slow blow.
High Voltage Power Supply
5.5 KV DC nominal.
Input Power
AC line power, internally selectable for 110/115 VAC-
50/60Hz or 220/230 VAC-50/60Hz.
Ion Emission
Steady state DC with sense feedback.
Mounting
Hanging apparatus attached to ceiling.
Ozone
Less than 0.05ppm
Weight
10 pounds
NOTE: Unauthorized servicing or modifications to your
ionizer will void the product warranty and may create
dangerous conditions. Servicing should be performed only
at the factory, or by a Desco EMIT approved technician.
© 2005 DESCO INDUSTRIES INC.
Employee Owned
DESCO EMIT WEST
- 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449
DESCO EMIT EAST
- 90 Hudson Road, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • DescoEMIT.com
Limited Warranty
Desco EMIT expressly warrants that for a period of one (1) year
from the date of purchase, Desco Emit Overhead Ionizers will be
free of defects in material (parts) and workmanship (labor). Within
the warranty period, a unit will be tested, repaired, or replaced at
our option, free of charge. Call our Customer Service Department
at 909-627-8178 (Chino, CA) or 781- 821-8370 (Canton, MA) for a
Return Material Authorization (RMA) and proper shipping instructions
and address. Include a copy of your original packing slip, invoice,
or other proof of purchase date. Any unit under warranty should be
shipped prepaid to the Desco EMIT factory. Warranty repairs will
take approximately two weeks.
If your unit is out of warranty, call our Customer Service
Department at 909-627-8178 (Chino, CA) or 01892 665313
(Crowborough, U.K.) for a Return Material Authorization (RMA) and
proper shipping instructions and address. Desco EMIT will quote
repair charges necessary to bring your unit up to factory standards.
Warranty Exclusions
THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF
ALL OTHER PRODUCT WARRANTIES, EXPRESSED AND
IMPLIED, INCLUDING MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE WHICH ARE SPECIFICALLY
DISCLAIMED. The express warranty will not apply to defects or
damage due to accidents, neglect, misuse, alterations, operator
error, or failure to properly maintain, clean or repair products
.
Limit of Liability
In no event will Desco EMIT or any seller be responsible or liable
for any injury, loss or damage, direct or consequential, arising out
of the use of or the inability to use the product. Before using,
users shall determine the suitability of the product for their intended
use, and users assume all risk and liability whatsoever in
connection therewith.