Figure 6: Mounting the console to the mounting plate

Figure 7: Inserting the disposable filter

Figure 8: Connecting the hose and disposable filter to the 

console

II.  Connect the hose and disposable filter to the console.

 

Press the disposable filter release button on the front of

 

the console to lock it down.  Push the fitting containing

 

the disposable filter all the way into the opening in the

 

console until it latches with a click.  It fits only in the

 

correct orientation.  The small plastic fitting on the end

 

of the disposable filter must align with the metal guide

 

coupling in the console.  You may have to wiggle the

 

disposable filter slightly while inserting it.

Choose a location that will be convenient to the work area 

and the gas supply.  The Console takes up very little space 

and is adaptable to a variety of permanent or temporary 

installations.  To minimize bends in the gun hose, orient the 

console so that the open end points toward the work area 

and the male connector points toward the air supply.
I.  Use the included screws to attach the supplied

 

mounting plate to the threaded holes on the back of the

 

console.

III.  Attach the included 1/4” NPT female quick connect

 

fitting to your gas supply line.  Slide the outer ring on

 

the fitting towards the supply line to insert the mating

 

fitting on the console.  You can attach the console

 

directly to the gas supply pipe or attach it using a hose

 

(not supplied).  If necessary, use a prefilter as defined

 

in the COMPRESSED GAS REQUIREMENTS section

 

of this technical bulletin.

IV.  If you would like to use the optional foot switch, plug its

 

cable to the jack located at the top of the console.

Operation

NOTE: Our recommendation is to set the pressure regulator 

on your air or nitrogen supply between 20 and 65 psi 

(0.14-0.45 MPa).  Discharge times vary depending on air 

pressure.

DESCO WEST

 - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 

DESCO EAST

 - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Website: 

Desco.com

Figure 5: Connecting the cable from the Wall Transformer 

to the back of the console

II.  Attach the plate to a flat surface, such as a wall or back

 

of a work bench, using suitable screws and fasteners.

 

When mounting to a hollow wall be sure to use #8

 

screws and 3/4” length anchors as a minimum.

MOUNTING TO A GAS SUPPLY

When a gas supply is close to the work area and fitted 

with a standard industrial interchange quick coupling, you 

may attach the console to the air supply fitting directly.  If 

necessary, use a prefilter as defined in the COMPRESSED 

GAS REQUIREMENTS section of this technical bulletin.

ASSEMBLY

NOTE: Protect the hose from sharp objects, abrasion, and 

high temperatures.  Do not pull or pinch the hose while 

assembling the components.
I.  Insert the larger diameter end of the air filter into the

 

end of the flexible air hose connector.  Press the metal

 

filter release tab at the end of the hose until it locks into

 

place.

Summary of Contents for 19590

Page 1: ...arge of 1000 V down to 100 V in less than one second at a distance of six inches 30 psi 0 2MPa inlet pressure Refer to the ESD Association ANSI ESD Standard STM3 1 for the test procedure The offset voltage balance is within 30 V of zero at a distance of six inches significantly less than the required limits of 50 volts per ANSI ESD S20 20 Necessary non conductors in the environment cannot lose the...

Page 2: ... Figure 4 19592 optional foot switch should be connected to the ion gun console Letter C in Figure 3 Installation COMPRESSED GAS REQUIREMENTS NOTE Failure to use clean dry air or nitrogen may result in damage to the Chargebuster Ion Gun that is not covered under the Limited Warranty The compressed gas supply must be clean dry air or nitrogen supplied by a delivery system that utilizes a refrigerat...

Page 3: ... the console directly to the gas supply pipe or attach it using a hose not supplied If necessary use a prefilter as defined in the COMPRESSED GAS REQUIREMENTS section of this technical bulletin IV If you would like to use the optional foot switch plug its cable to the jack located at the top of the console Operation NOTE Our recommendation is to set the pressure regulator on your air or nitrogen s...

Page 4: ...egins to look dirty I Turn power off at the console and disconnect the console from the gas supply II Hold down the disposable filter release button on the side of the console III Remove the hose and disposable filter from the console by pulling the textured rubber plug where the hose emerges from the console Rocking the plug back and forth can help loosen the filter Do not pull the hose itself IV...

Page 5: ...rranty call Customer Service at 909 627 8178 Chino CA or 781 821 8370 Canton MA for a Return Material Authorization RMA and proper shipping instructions and address Desco Charleswater will quote repair charges necessary to bring your unit up to factory standards Warranty Exclusions THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES EXPRESSED AND IMPLIED INCLUDING MERCHA...

Reviews:

Related manuals for 19590