Specifications

Input:

 

19500

 

120 VAC - 50/60 Hz - 3.0 Amps

 

19520

 

220 VAC - 50/60 Hz - 1.5 Amps

Fuse Type:

 

19500

 

Slow blow 5 amp

 

19520

 

Slow blow 3 amp

Output:  

4.5kV at 50 - 60 nano amps

Air Flow: 

Adjustable 117 CFM maximum

Balance Voltage*:  ±5V
Dimensions: 

11" x 9" x 7"

Weight:

 

19500

 

13 Pounds

 

19520

 

16 Pounds

Cord:

 

19500

 

Cord with three wire IEC plug 

 

(ground required)

 

19520

 

Not included

*Desco ionizers meet the ANSI/ESD S20.20 minimum 

recommended technical requirement range of less than ±50 

Volts voltage offset tested in accordance with ANSI/ESD 

STM3.1.  Desco models 

19500

 and 

19520

 greatly exceed 

the requirement providing ±5 Volt auto-balancing.

Limited Warranty

Desco expressly warrants that for a period of one (1) year from the date 

of purchase Desco Ionizers will be free of defects in material (parts) and 

workmanship (labor).  Within the warranty period, a credit for purchase 

of replacement Desco Ionizers, or, at Desco’s option, the Ionizer will be 

repaired or replaced free of charge.  If product credit is issued, the amount 

will be calculated by multiplying the unused portion of the expected one 

year life times the original unit purchase price. Call our Customer Service 

Department at 909-627-8178 (Chino, CA) or 781-821-8370 (Canton, MA) 

for a Return Material Authorization (RMA) and proper shipping instructions 

and address. Please include a copy of your original packing slip, invoice, 

or other proof of date of purchase. Any unit under warranty should be 

shipped prepaid to the Desco factory. Warranty replacements will take 

approximately two weeks.
If your unit is out of warranty, call our Customer Service Department at 

909-627-8178 (Chino, CA) or 781-821-8370 (Canton, MA) for a Return 

Material Authorization (RMA) and proper shipping instructions and 

address. Desco will quote repair charges necessary to bring your unit up 

to factory standards.

Warranty Exclusions

THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF 

ALL OTHER PRODUCT WARRANTIES, EXPRESSED AND IMPLIED, 

INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR 

PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED. The express 

warranty will not apply to defects or damage due to accidents, neglect, 

misuse, alterations, operator error, or failure to properly maintain, clean or 

repair products.

Limit of Liability

In no event will Desco or any seller be responsible or liable for any injury, 

loss or damage, direct or consequential, arising out of the use of or 

the inability to use the product. Before using, users shall determine the 

suitability of the product for their intended use, and users assume all risk 

and liability whatsoever in connection therewith.

TP1

+ >60
- >60

12"

12"

12"

12"

12"

TP4

+ >60
- >60

TP7

+51.0
-59.0

TP10

+25.0
-38.0

TP2

+1.3
-1.5

TP5

+1.9
-2.5

TP8

+2.8
-3.6

TP11

+3.7
-4.9

TP3

+ >60
- >60

TP6

+ >60
- >60

TP9

+35.0
-41.0

TP12

+21.0
-26.0

Bench Top

Blower Ionizer

Air Flow

Charged Plate

12"

Figure 10.  Neutralization (Discharge) Times of item 

19520

 at 230VAC, 50Hz input

Summary of Contents for TB-2016

Page 1: ...ess mainly focus on the distribution of electronic components Line cards we deal with include Microchip ALPS ROHM Xilinx Pulse ON Everlight and Freescale Main products comprise IC Modules Potentiometer IC Socket Relay Connector Our parts cover such applications as commercial industrial and automotives areas We are looking forward to setting up business relationship with you and hope to provide you...

Page 2: ...ing the dissipative workstation Ionization is not effective on items that have large capacitance like people and carts however ionizers should be considered as a method for charge neutralization in cases where grounding cannot be achieved Air ionization can neutralize the static charge on insulated and isolated objects by producing separate charges in the molecules of the gases of the surrounding ...

Page 3: ...r press firmly to ensure that the cord is properly attached Install the power cord into a properly grounded outlet The ionizer must be grounded for proper operation Desco recommends the 19219 Ground Hub Continuous Monitor or 98130 AC Outlet Analyzer to check the ground Operation Turn on the power switch and adjust fan speed for the desired air flow Higher air flow will result in a faster neutraliz...

Page 4: ...djusts the unit to reach an equilibrium at low offset voltage or balanced ion flow The ionizer is designed to achieve balance under extreme conditions and is uniquely able to maintain balance in most any environment Ions are emitted in an efficient laminar flow This reduces air turbulence and ion recombination prolongs cleanliness and increases efficiency The ionizer s unique tri metallic ion emit...

Page 5: ...TP1 60 60 12 12 12 12 12 TP4 60 60 TP7 28 0 32 0 TP10 18 0 20 0 TP2 1 2 1 4 TP5 1 5 2 0 TP8 2 3 3 0 TP11 3 1 4 0 TP3 60 60 TP6 60 60 TP9 20 0 23 0 TP12 15 0 20 0 Bench Top Blower Ionizer Air Flow Charged Plate 12 Figure 8 Neutralization Discharge Times of item 19500 at 120VAC 60Hz input TP1 60 60 12 12 12 12 12 TP4 60 60 TP7 38 0 46 0 TP10 21 0 28 0 TP2 1 4 1 6 TP5 2 0 2 5 TP8 2 9 3 7 TP11 3 9 4 9...

Page 6: ... for a Return Material Authorization RMA and proper shipping instructions and address Please include a copy of your original packing slip invoice or other proof of date of purchase Any unit under warranty should be shipped prepaid to the Desco factory Warranty replacements will take approximately two weeks If your unit is out of warranty call our Customer Service Department at 909 627 8178 Chino C...

Reviews:

Related manuals for TB-2016