Neutralization (Discharge) Times
All time measurements are in seconds.
NOTE: Discharge times in seconds are representative only and are not a guarantee. Discharge times are actual
measurements recorded in a factory ambient environment.
TP1
+ > 60
- > 60
12"
12"
12"
12"
12"
TP4
+40.4
-47.1
TP7
+12.4
-21.5
TP10
+12.3
-13.5
TP2
+1.0
-1.1
TP5
+2.6
-3.3
TP8
+4.9
-6.0
TP11
+7.3
-9.8
TP3
+ > 60
- > 60
TP6
+26.3
-34.6
TP9
+14.3
-16.6
TP12
+11.9
-15.1
Trustat
Bench Top Ionizer
Charged Plate
12"
Figure 6. Neutralization (Discharge) Times at 120VAC / 220VAC, 60Hz input
Optimal
Coverage
Area
Air Flow