Neutralization (Discharge) Times

All time measurements are in seconds.
NOTE: Discharge times in seconds are representative only and are not a guarantee.  Discharge times are actual 

measurements recorded in a factory ambient environment.

TP1

+ > 60
- > 60

12"

12"

12"

12"

12"

TP4

+40.4
-47.1

TP7

+12.4
-21.5

TP10

+12.3
-13.5

TP2

+1.0
-1.1

TP5

+2.6
-3.3

TP8

+4.9
-6.0

TP11

+7.3
-9.8

TP3

+ > 60
- > 60

TP6

+26.3
-34.6

TP9

+14.3
-16.6

TP12

+11.9
-15.1

Trustat

 

Bench Top Ionizer

Charged Plate

12"

Figure 6.  Neutralization (Discharge) Times at 120VAC / 220VAC, 60Hz input

Optimal 

Coverage

Area

Air Flow

Summary of Contents for TRUSTAT 04622

Page 1: ...parate negative and positive ion emitters connected by a pair of high voltage cables to their respective high voltage power supplies The two polarities alternately pulse on and off to limit ion recombination The ionizer s one speed fan 77 CFM produces consistent performance within the coverage area The Trustat Bench Top Ionizer features a powder coated steel enclosure February 2015 The Trustat Ben...

Page 2: ...er second or up to 20 pulses per second Turn the potentiometer clockwise to increase the rate Turn the potentiometer counter clockwise to decrease the rate D Power LED Illuminates blue when the ionizer is powered ON E Pulse Rate LEDs Illuminates red when positive ions are emitted and green when negative ions are emitted Installation Place the unit at a desired location where the airflow will not b...

Page 3: ...07 Replacement Emitter Points are available for purchase Compliance Verification Compliance Verification should be per ESD TR53 Offset voltage balance and both polarity s discharge time should be checked on every ionizer periodically using an Ionization Test Kit or a Charged Plate Analyzer Clean the emitter points with electrical power off adjust offset voltage balance to zero and then re test for...

Page 4: ...E Discharge times in seconds are representative only and are not a guarantee Discharge times are actual measurements recorded in a factory ambient environment TP1 60 60 12 12 12 12 12 TP4 40 4 47 1 TP7 12 4 21 5 TP10 12 3 13 5 TP2 1 0 1 1 TP5 2 6 3 3 TP8 4 9 6 0 TP11 7 3 9 8 TP3 60 60 TP6 26 3 34 6 TP9 14 3 16 6 TP12 11 9 15 1 Trustat Bench Top Ionizer Charged Plate 12 Figure 6 Neutralization Disc...

Page 5: ...tungsten for improved mechanical strength and ionization stability High Voltage Power Supply 5 5kV DC nominal Input Power AC line power 100 120 VAC 50 60Hz 04622 220 230 VAC 50 60Hz 04623 IEC C14 style inlet Ion Emission Pulse DC Ozone 0 05 ppm Weight 3 6 lbs 1 6 kg Limited Warranty Warranty Exclusions Limit of Liability and RMA Request Instructions See Desco Terms and Conditions TP1 60 60 12 12 1...

Reviews: