Maintenance
“All ionization devices will require periodic maintenance
for proper operation. Maintenance intervals for ionizers
vary widely depending on the type of ionization
equipment and use environment. Critical clean room
use will generally require more frequent attention. It
is important to set up a routine schedule for ionizer
service. Routine service is typically required to meet
quality audit requirements.” [CLC/TR 61340-5-2 User
guide Ionization sub-clause 4.7.6.7 Maintenance and
cleaning]
EIA-625, recommends checking ionisers every 6
months, but this may not be suitable for many programs
particularly since an out-of-balance may exist for
months before it is checked again. EN 61340-5-1 clause
5.2.4 Compliance Verification Plan states: “The test
equipment selected shall be capable of making the
measurements defined in the compliance verification
plan.”
Cleaning the Emitter Point
To maintain optimum neutralisation efficiency and
operation, cleaning should be performed on a regular
basis. Use the Desco Europe
200155
Emitter Point
Cleaners or a swab dampened with isopropyl alcohol to
clean the ion gun’s emitter point.
1. Disconnect the ion gun from its power supply and
air supply.
2. Remove the nozzle.
3. Gently clean the emitter point using a swab
dampened with Isopropyl alcohol. Screw the nozzle
back onto the ion gun when complete.
Neutralisation (Discharge) Times
All measurements were taken from ±1,000 V to ±100 V
at a distance of 6 inches (15 cm).
Air Pressure
(psi)
15
29
44
58
73
87
+ Discharge
(seconds)
.5
.3
.3
.2
.2
.2
- Discharge
(seconds)
.6
.3
.3
.2
.2
.2
Specifications
Power Supply Input
Voltage
100-240 VAC, 50/60 Hz
Power Supply Output
Voltage
24 VDC
Operating Temperature 32ºF to 104ºF (0 to 40ºC)
Dimensions
6.5" x 5.4" x 1.0"
(165 mm x 136 mm x 25
mm)
Weight
0.4 lbs (0.2 kg)
Balance
±15 V
Ozone
<0.04 ppm
Supply Pressure
7 psi to 87 psi
Minimum Airflow
13 CFM
Gas Input
Clean Dry Air (CDA)
Gas Connection
6 mm port
Enclosure
Gun - PBT polymer
Nozzle - PPS polymer
Limited Warranty, Warranty Exclusions, Limit
of Liability and RMA Request Instructions