Please make sure that following testing procedure is done in a relaxed manner. Pay close attention to the testing procedure
and allow yourself adequate time to execute the testing and understand the equipment.
Before you begin testing, the following assumptions are made: The ARC unit(s) have a set of a fresh
batteries installed. The STM surface station is properly connected to PC and the “Acoustic Release
Control” software is already running.
During the testing procedure, monitor the status LED of the ARC unit. The status LED is located
inside the body of the ARC station and can be visualized in a dimmed environment, shade, or a dark
room.
The location of the LED in ARC unit.
Status LED
Pattern
Description
LED is off
ARC unit is in “sleep” mode, passively listening for the sonar commands or
batteries are discharged
Single short
blink
ARC unit is “awake” and standing by for commands
Double blink
ARC unit is sending/receiving sonar signals to/from the STM surface station
Summary of Contents for Acoustic Release Control System
Page 3: ......
Page 25: ......
Page 33: ... Control Panel Device Manager Ports COM LPT ...
Page 35: ......
Page 44: ...STEP 6 Click Continue button The ARC unit will be added to the main window s list ...
Page 62: ......