background image

23

5.5.1. 

C

HARGING YOUR MOTORIZED CYLINDER

You can clean external surfaces by soft, slightly damp cloth. Never use abrasive chemicals or water for this purpose. Don’t 
try to disassemble your motorized cylinder. 

5

.

5.

 

MAINTENANCE

If you hear three short tones after operation of the motorized cylinder or if the rotation speed is too slow compared to 
normal working speed, you need to charge your motorized cylinder. 

Importan

t

- You may use your motorized cylinder as it is always connected to charger. The device will automatically 
adjust itself to work as always connected. (valid for firmware version 72 and higher.)

- If you are leaving your home for an extended period of time, first fully charge your motorized cylinder and 
take your mechanical key with you.  If you would leave 

more than 2 months

, after charging your motorized 

cylinder, either shift the motorized cylinder to child lock mode or leave your device as it is connected to 
charger. 

Otherwise, the batteries of your product 

.

would die due to deep discharge

- Charging period of the device is around 3 hours. We recommend to charge it under supervision and at least  
once in two months even if the batteries are not empty. Use provided charger and cable. With your own risk, 
you can use  any 5 V DC microUSB chargers or a powerbank. Use 

high quality

 chargers, cables and 

powerbanks 

only

Summary of Contents for Utopic R OK

Page 1: ...USER MANUAL Wireless Motorized Cylinder ...

Page 2: ...r bag etc GENERAL INFORMATION and WARNINGS If there is any problem with the door or the locking mechanism first of all those problems have to be solved The door s mechanical parts and locking mechanism have to work properly Auto rotating parts of the device can cause injuries during installation BE CAREFUL If you are leaving your home for an extended period of time first fully charge your motorize...

Page 3: ...NT Mayvaryaccordingtomodel 1 FEATURES OF THE DEVICE Euro Profile Batteries and Battery Life 60 days Both RF and BLE are active Compatible Cylinder Type ISM RF 434 Mhz According to DESi labratory tests with a usage of 10 operations per day on a 2 turns lock battery life of motorized cylinder is as follows Structure ABS Plastic 90 days Either RF or BLE is active Communication Capability Your motoriz...

Page 4: ...tons Handle for Manual Operation Charging Port microUSB Fixing Screws 4 pcs Fixing Screws 4 pcs Slot for The Modified Key VERTICAL HORIZONTAL Min 2 mm Outside The existing cylinder should come out at least 2 mm to be caught by motorized knob Type A Important ...

Page 5: ...rized knob on the cylinder where the arrrows on the key slot point upward and the modified key is in the position that it can be taken out from the cylinder without rotating could be either horizontal or vertical First tighten 4 fixing screws lightly then tighten them firm Follow the steps below to install motorized knob to the existing cylinder 5 mm Cut the key Keep the modified key in the position t...

Page 6: ...TALLATION TYPE B Min 4 mm Outside The existing cylinder should come out at least 4 mm to be caught by motorized knob Type B Important Fixing Screws 2 pcs Gripping Screws 2 pcs The Slot for Modified Key VERTICAL HORIZONTAL MODIFIED KEY MODIFIED KEY In some models MODIFIED KEY 2 way slot 1 way slot ...

Page 7: ... tighten 2 gripping screws and then tighten 2 fixing screws If your device has 2 way slot mark the key 5 mm from the surface of cylinder If your device has 1 way slot mark the key 7 mm from the surface of cylinder INSTALLATION TYPE B Follow the steps below to install motorized knob to the existing cylinder Insert one of exiting keys to the cylinder 5 or 7 mm Cut the key in accordance with slot type...

Page 8: ... motorized cylinders around Press and hold two buttons on motorized cylinder until you hear a long warning tone and then release buttons After that you will hear a short warning tone All the requested permissions need to be given without any restriction 5 1 ENROLLING A MOBILE PHONE AS MASTER CONTROLLER 5 SETTING UP YOUR DEVICE NOTE For Android phones when you are installing the app it will ask per...

Page 9: ...s of motorized cylinder Before using your motorized cylinder you should adjust it properly by setting locking way and then number of rotation according to your lock If you want to change the master controller of motorized cylinder please check HOW TO RESET MOTORIZED CYLINDER topic on the last page NOTE For Android phones when you are installating the application it will ask permissions All the req...

Page 10: ... touch the menu button in the top right corner when it is not connected to motorized cylinder you will reach settings menu of application Related menu items are as follows FAQ You can see questions and answers about usage APPLICATION INFO You can see the version of installed application VIDEOS You can see videos about usage of motorized cylinder Menu Button ...

Page 11: ...of connected motorized cylinder You can change settings of your motorized cylinder and perform administrative activities via this menu Related menu has 4 tabs Device Info Knob Settings Users Reports Number of Enrolled Controllers Users Device Type If you want to delete connected device from your mobile application touch the Delete Device button in this menu In this tab you can see following inform...

Page 12: ...ally in 15 30 45 or 60 seconds after it is unlocked If you enable auto locking you will see DAY MODE setting which gives flexiable options for office use Menu Button Knob Settings Tab If DAY MODE is enabled you can define 1 or 2 periods for selected days which Auto Locking will not work INVERT LOCKING WAY You should set locking way of the device in accordance with your door s locking way ADJUST NU...

Page 13: ...PAGE BUZZER OF KNOB You can enable disable activation sounds coming from motorized cylinder Moderate and High If you use the device with a multi point or security door lock use moderate level Advanced Settings Page MOTOR TYPE If your motorized cylinder is equipped with coreless motor you need to change motor type to coreless You can get detailed information from your dealer about coreless motor Ve...

Page 14: ...by one Menu Button Users Tab Touch to reach dedicated user page Besides managing contollers you can generate and send one time limited time access passwords by touching Create One Time Code line Details will be explained on page 18 19 and 20 Please note that you cannot delete Master Controller till you the FACTORY RESET motorized cylinder If you touch Delete All Contollers line all enrolled contro...

Page 15: ...he new controller as explained below 5 3 3 1 ENROLL NEW CONTROLLER Your motorized cylinder may learn up to 40 controllers DESi For keypad wake it up and touch the locking button For remote controller press and hold any button DESi For home automation interface power up the device and short circuit and then open circuit yellow and black cables 3 12 V DC For other controllers send locking or unlocki...

Page 16: ...ect to smart lock MASTER MOBILE PHONE touch menu button in the top right corner and go to Users tab On Users tab touch Enroll New Controller line to go enrolling new contoller page After that touch to Green Plus sign next to Enroll New Controller line Smart lock will give a long 5 sec and then a short warning tones With NEW MOBILE PHONE Touch on the top left corner to see the list of Utopic smart ...

Page 17: ...Utopic application to your mobile phone launch the app choose the language and set a password if you want Touch to Settings icon located on upper right corner and go to Users tab Touch to Create One Time Code than Via App Launch the app on the master mobile phone and choose the motorized cylinder that you want to generate the code 5 3 3 3 a ONE TIME ACCESS VIA APPLICATION If you want to limit the ...

Page 18: ...nfirm The application searches available motorized cylinders around and when it finds it will ask to use the code on the clipboard with a pop up Touch the confirm button When you see the code as it is written on the screen touch to Green Tick to unlock the door 5 3 3 3 b TIME LIMITED ACCESS VIA WIRELESS KEYPAD The Wireless Keypad is sold separately as an accessory Wake the keypad up by touching your ...

Page 19: ... Time Code line After enabling Time Limited Access Mode on keypad follow the steps below to enroll it to the motorized cylinder After choosing the role you will see following titles to set on coming page Check In Out Time Default check in time is 14 00 and check out time is 10 00 This period is valid for all the time After warning tones wake the keypad up by putting your palm to the touch keys and...

Page 20: ...re generated information by touching related button Unlocking The Door Via Keypad By Using 8 Digit Time Limited Access Code Wake the keypad up and enter the 8 digit code If it is valid the motorized cylinder will unlock the door After first succesful usage of the 8 digit code you can use last 4 digits of code during the period You should change the default master password of the keypad before using...

Page 21: ... cancelled automatically So it will not work in October too If you generate a multi usage code whose validity interval begins in a month and ends in next month and if the code is not used in first month it will be cancelled automatically as explained below 5 3 4 REPORT TAB IMPORTANT NOTES You can generate time limited access codes while you are away Bluetooth or internet connection is not necessary...

Page 22: ...the door You can also unlock and open the door via button on motorized cylinder For emergency conditions the handle and key also can unlock and open the door 5 4 2 LOCKING THE DOOR You can also lock the door via button on motorized cylinder For emergency conditions the handle and key also can lock the door To enable child lock press and hold two buttons on the motorized knob till you hear a long 3...

Page 23: ...ted valid for firmware version 72 and higher If you are leaving your home for an extended period of time first fully charge your motorized cylinder and take your mechanical key with you If you would leave more than 2 months after charging your motorized cylinder either shift the motorized cylinder to child lock mode or leave your device as it is connected to charger Otherwise the batteries of your...

Page 24: ...lock press two buttons on motorized cylinder and wait till you hear 3 short warning tones The mechanical key would be cut shorter during installation Please check page 5 and 7 for details There would be a problem related with connection between motor and rotating shaft Call your dealer and ask for service Batteries of motorized cylinder may be weak Recharge the batteries I CANNOT ADJUST THE SETTIN...

Page 25: ...ion need to be given without any restriction If you did not allow the app to reach requested permission you need to uninstall then reinstall the application and allow the requested permissions during installation If you have this issue during enrolling your phone to the motorized knob maybe you foget to shift the motorized knob to enrolling mode Please check pages 8 14 and 16 for details about enr...

Page 26: ... to get it back As a solution you need to delete the application and reinstall it However in this case your phone will not recognize your smart lock You must reset your smart lock and enter the smart lock to the pair mode If your motorized knob s software firmware version is below 80 you cannot create a temporary access code via application To use this feature you need to upgrade your motorized kn...

Page 27: ...ce Info Tab Make sure master phone s and motorized knob s charge level are at least 50 during the update process Make sure that the Bluetooth connection does not lost and the application does not close If your phone has an automatic screen lock always turn off this feature during the update The update process will take approximately 10 minutes During this time keep the phone close to motorized kno...

Page 28: ...te all controllers enrolled to the device you can reset your motorized knob as follows Press and hold 2 buttons on the motorized knob A long warning tone will be heard Continue to hold the buttons After a while second warning tone will start After a while double tone and then triple tone will be heard and all the controllers including master controller enrolled to the device will be deleted After ...

Page 29: ...29 NOTES ...

Page 30: ...copyright DESi Alarm and Security Systems Inc www desi com tr ...