18
4.3.9. DELAYED LOCKING FEATURE (MA)
Your motorized cyclinder has a delayed locking feature which locks itself 5 second after you press the locking button on
the motorized cylinder. If this feature is enabled, when you are going out, if you touch locking button on motorized
cylinder and close the door in 5 seconds, it will lock the door automatically. You can enable or disable this feature by
following steps below:
- Touch “WAKE UP”. Two arrows will appear on display. Than touch “2”. “AD” will be shown.
- Put one of the master fingers to the reader. First “OK” and than “LR” will be shown.
- Touch to “2" till “MA” appears and touch to “1" when “MA” is displayed. ”M0" or “M1" will be shown.
- Touch to “1" to toggle between;
“M0” - delayed locking is disabled,
“M1” - delayed locking is enabled.
- When desired choice is displayed, touch to “2". “OK” will be displayed.
In this way, desired delayed locking choice will be set. Schematic representation of enabling delayed locking is as follows:
N
OTE
:
To transfer settings to motorized cylinder, you need to lock or unlock motorized cylinder via master controller.