3.3.2.1. KNOB SETTINGS TAB
ADVANCED SETTINGS PAGE
BUZZER OF KNOB:
You can enable / disable activation sounds coming from
smart lock
.
INVERT LOCKING WAY
: You should set locking way of the device in accordance with your door’s
locking way.
ADJUST NUMBER OF TURNS: You should set how long the device will rotate to lock the door in
accordance with your door’s lock. For this purpose, close the door (do not lock) and then “Blue
Rotating Arrow” button. The device will retract the latch, lock and then unlock the door.
LATCH RETRACTION PERIOD:
You can adjust the time period which the
smart lock
keeps latch of the
lock inside when it unlocks the door.
(1 sec - 3 sec - 6 sec). 0 sec is for the doors without latch.
MOTOR
POWER
: You can adjust the power (and also speed) of motor in 4 different levels, adjust to the lowest
level which can lock and unlock your door without any problem. Higher powers will decrease battery
life.
MOTOR TYPE:
If your
smart lock
is equipped with coreless motor, you need to change motor type to
coreless. If you have a device with coreless motor and if it cannot keep the latch of the lock inside,
enable “Power Hold” option.
NOTE 1:
LATCH RETRACTION PERIOD, MOTOR POWER, MOTOR TYPE features are only available for device type
N2 and firmware version is 87 or higher.
NOTE 2:
Utopic2 Gold Edition models have coreless motor, please be sure that coreless motor is set. Otherwise your
smart lock will not work properly.