XL™ Series
Counter And Frequency Inputs 13-3
PC Interface View Built In Display Screen
S - Slope: 0.01
Ctr Slp [0.01 ]
This option allows the user to define a slope value that will be applied to each count (switch
closure) in order to calculate the values of both counters. The default value is 0.01 so that when
connected to a tipping bucket rain gauge each tip or count (switch closure) is equal to 0.01 inches
of rain.
PC Interface View Built In Display Screen
I - Count Interval: Daily
Cnt Interval [Daily ]
This option allows the user to select the count interval which will determine how often and when
the interval counter will be reset 0.00. The default interval is “Daily,”. Valid options are:
Daily
When the count interval is set to “Daily,” the Counts value will report the number
of counts since midnight. The Counts value will be reset to 0.00 every midnight
after all scanning and report processes have completed.
Hourly
When set to “Hourly,” the Counts value will report the number of counts since the
top of the last hour.
Scan
If set to “Scan,” the Counts value will report the number of counts since the last
scan.
01 Jan
Resets the ‘Counts’ value to 0.00 on the first scan of January 1 of each year.
st
01 Oct
Resets the ‘Counts’ value to 0.00 on the first scan of October 1 of each year.
st
Several agencies use October 1 as the start of the ‘water year’.
st
PC Interface View Built In Display Screen
M - Counter Mode: Off
Ctr Mode [Off]
This option allows the user to select the counter mode of operation. The default mode is “Count
Only”. If enabled, the counters will be active, even if scanning is turned off. Valid options are:
Off
Counters are disabled.
Count Only
Both counters are enabled.
Summary of Contents for H-350XL
Page 1: ...XL Series Models H 350XL H 500XL H 510XL H 522 H 522 Plus Owner s Manual ...
Page 30: ...2 16 Hardware Options and Installation XL Series ...
Page 42: ...3 12 Using The Built In Keypad Display XL Series ...
Page 46: ...4 4 PC Menu Interface Operation XL Series ...
Page 58: ...5 12 Miscellaneous System Setup XL Series ...
Page 66: ...6 8 Serial Port Options XL Series ...
Page 74: ...7 8 System Configuration Files XL Series ...
Page 84: ...8 10 System Status Menus Options XL Series ...
Page 88: ...9 4 Scanning Options XL Series ...
Page 156: ...15 12 Logging Options XL Series ...
Page 198: ...16 42 Operation with the GOES Radio XL Series ...
Page 216: ...19 6 Alarm Call Out XL Series ...
Page 234: ...21 8 Operation with the H 355 Smart Gas System XL Series ...
Page 246: ...22 12 Functions XL Series ...