XL™ Series
SDI-12 Operations 14-9
14.4 SDI-12 Sensor Mode
The XL™ can be configured as an SDI-12 sensor when used with other data loggers. SDI-12
sensors will have a unique address and will measure between 1 to 9 data values. The options
under this menu allow the user to select what address the XL™ will respond to and what data
will be returned to the external data logger.
Built in Menu Structure: SDI-12 Sensor Mode Options.
System Setup ->
Sensor Mode Setup ->
Sensor Mode Enabled
Sensor Mode Adrs [X]
SDI Meas. Time = XXX
Par 1 Source[XXXXXX]
:
Par 9 Source[XXXXXX]
Par 1 Digits[2]
:
Par 9 Digits[2]
PC Menu Screen: SDI-12 Sensor Mode Options.
Sensor Mode Setup (Esc to Return)
SDI-12 Sensor Mode Status: Enabled
A - SDI-12 Address: 0
T - Total Measurement Time: 7
1 - Parameter 1: Stage B - Digits: 2
2 - Parameter 2: PSI C - Digits: 2
3 - Parameter 3: PtTemp D - Digits: 2
4 - Parameter 4: None E - Digits: 2
5 - Parameter 5: None F - Digits: 2
6 - Parameter 6: None G - Digits: 2
7 - Parameter 7: None H - Digits: 2
8 - Parameter 8: None I - Digits: 2
9 - Parameter 9: None J - Digits: 2
Enter Option >
PC Interface View Built In Display Screen
Summary of Contents for H-350XL
Page 1: ...XL Series Models H 350XL H 500XL H 510XL H 522 H 522 Plus Owner s Manual ...
Page 30: ...2 16 Hardware Options and Installation XL Series ...
Page 42: ...3 12 Using The Built In Keypad Display XL Series ...
Page 46: ...4 4 PC Menu Interface Operation XL Series ...
Page 58: ...5 12 Miscellaneous System Setup XL Series ...
Page 66: ...6 8 Serial Port Options XL Series ...
Page 74: ...7 8 System Configuration Files XL Series ...
Page 84: ...8 10 System Status Menus Options XL Series ...
Page 88: ...9 4 Scanning Options XL Series ...
Page 156: ...15 12 Logging Options XL Series ...
Page 198: ...16 42 Operation with the GOES Radio XL Series ...
Page 216: ...19 6 Alarm Call Out XL Series ...
Page 234: ...21 8 Operation with the H 355 Smart Gas System XL Series ...
Page 246: ...22 12 Functions XL Series ...