XL™ Series
Logging Options 15-9
TmMax:
This will log the time that a max value was found based on the samples between two log
intervals or based on a subset of the data values. For example lets say a column is set to log
stage every 15 minutes using a function of Max_S and a second column is set to log stage every
15 minutes using a function of TmMax and the scan rate is set to 1 minute. That means there
will be 15 scans for each log and the first column will log the maximum stage value out of the 15
readings. The second column will not log the stage value but will log the time that the maximum
stage value occurred.
TmMin:
This will log the time that a min value was found based on the samples between two log intervals
or based on a subset of the data values. For example lets say a column is set to log stage every
15 minutes using a function of Min_S and a second column is set to log stage every 15 minutes
using a function of TmMin and the scan rate is set to 1 minute. That means there will be 15
scans for each log and the first column will log the minimum stage value out of the 15 readings.
The second column will not log the stage value but will log the time that the minimum stage
value occurred.
Sum_S:
This will add up the scanned values for the column for the log rate period and log one value at
the end of the log rate. For example, lets say there are two columns set up to report counts. The
first is set up to report counts on every scan and the second is set with a log rate of 1 hour so it
will report only once an hour with a total count for that hour.
Avg_T:
This will average every scan regardless of the log rate. If the scan rate is 15 minutes and one
column is set up to log the water level of a lake with a log rate of 15 minutes and a column
function of NOW, and a second column is set up to log the same data with a log rate of 1 hour
and the column function set to AVG_T, the first column will log the current lake level every 15
minutes. The second column would log a value once an hour because the log rate is set to 1 hour,
but the value would be the average water level since scanning was turned on. All values scanned
since scanning was enabled would be included in the average.
Max_T:
This would log the maximum data value scanned since scanning was enabled. The value would
be logged based on the log rate. This data value would be like a crest stage gage showing the
highest water level since scanning started.
Min_T:
This would log the minimum data value scanned since scanning was enabled. The value would
be logged based on the log rate. This could be used to see what the minimum battery has been
since scanning was turned on.
Sum_T:
Summary of Contents for H-350XL
Page 1: ...XL Series Models H 350XL H 500XL H 510XL H 522 H 522 Plus Owner s Manual ...
Page 30: ...2 16 Hardware Options and Installation XL Series ...
Page 42: ...3 12 Using The Built In Keypad Display XL Series ...
Page 46: ...4 4 PC Menu Interface Operation XL Series ...
Page 58: ...5 12 Miscellaneous System Setup XL Series ...
Page 66: ...6 8 Serial Port Options XL Series ...
Page 74: ...7 8 System Configuration Files XL Series ...
Page 84: ...8 10 System Status Menus Options XL Series ...
Page 88: ...9 4 Scanning Options XL Series ...
Page 156: ...15 12 Logging Options XL Series ...
Page 198: ...16 42 Operation with the GOES Radio XL Series ...
Page 216: ...19 6 Alarm Call Out XL Series ...
Page 234: ...21 8 Operation with the H 355 Smart Gas System XL Series ...
Page 246: ...22 12 Functions XL Series ...