XL™ Series
Functions 22-7
counts
This will cause the system to read the latest summation count value
and return the results. The results are adjusted for the count slope
coefficient.
totcnt
This will cause the system to read the last total count value
and return the results. The results are adjusted for the count
slope coefficient.
digioX
This will cause the system to read the digital I/O X and return a 1.0
if it is high and a 0.0 if it is low. X is a 1 or a 2 representing digital
I/O 1 or 2.
anaX
This will cause the system to read analog channel X, apply
the slope and offset for analog channel X, and return the
results. X is from 1 to 4.
freq
The system will read the frequency input, apply the slope and
offset for the frequency input, and return the results.
encodr
The unit can use the two digital inputs to read the older style
quadrature shaft encoders. If the system is configured for this type
of encoder, this would cause the encoder to be read and the results
to be returned.
tscans
This is the total number of scans since logging started. This
can be used as a counter or to initialize some variables at
the start of scanning.
sdiAP
This will cause the system to scan the sensor at SDI-12
address A and return parameter P as the result. The address
is in the range of 0 to 9 and the parameter is in the range of
1 to 9.
fntXX
Functions may be called from other functions or used as
variables for other functions. The value of the referenced
function is returned but the referenced function is not
reevaluated. See the section on advanced operations for
details. The value of XX is 01 to 40 for fnt01 to fnt40.
System Constants:
There are a few constants the system recognizes so the user does not have to type them in
directly. They are all implemented to the highest precision possible.
pi
The value for
pi
is 3.14159265359.
Summary of Contents for H-350XL
Page 1: ...XL Series Models H 350XL H 500XL H 510XL H 522 H 522 Plus Owner s Manual ...
Page 30: ...2 16 Hardware Options and Installation XL Series ...
Page 42: ...3 12 Using The Built In Keypad Display XL Series ...
Page 46: ...4 4 PC Menu Interface Operation XL Series ...
Page 58: ...5 12 Miscellaneous System Setup XL Series ...
Page 66: ...6 8 Serial Port Options XL Series ...
Page 74: ...7 8 System Configuration Files XL Series ...
Page 84: ...8 10 System Status Menus Options XL Series ...
Page 88: ...9 4 Scanning Options XL Series ...
Page 156: ...15 12 Logging Options XL Series ...
Page 198: ...16 42 Operation with the GOES Radio XL Series ...
Page 216: ...19 6 Alarm Call Out XL Series ...
Page 234: ...21 8 Operation with the H 355 Smart Gas System XL Series ...
Page 246: ...22 12 Functions XL Series ...