background image

Drill a hole on floor with

1/2" dia,1"deep , and align

center of bolt in lower box.

Fix the ciamp to connecting

tube in midway.

2"

2 7/16"

13/32"

STEP 1 

DIRECTIONS FOR CHANGING

                 HANDING OF DEVICE

           Handing of device is preset at factory

           for RHR.To change handing of device,

           follow steps shown below and see 

           DRAWING FOR STEP 1.

           1.Loosen screws ’A’ and remove screw

              ‘B’ and spring ‘C’.

           2.Reverse the postions of screw ’B’ and

              spring ‘C’ and then tighten screw ‘A’.

           3.The device is now set for LHR.

  

STEP 2

MARK CENTER LINE ON DOOR

              Mark center line on inside of door. 

              Establish the horizontal center line of 

              the device by drawing a line across 

              the door 40” above floor line. 

 

 

STEP 3

MARK DOOR AND DRILL HOLES

           1.Fold and apply template (A) to edge of 

              door and mark door as indicated on 

              template (A).

           2.Drill holes A X 6 in accordance with the

              diameters as indicated on template (A)

STEP 7 

INSTALL BOTTOM LATCH 

                ASSEMBLY

           1.Align vertical center line of bottom

              latch assembly and lower connecting tube

              as shown on template. Mark door as

              indicated on template (B-2).

             

 CAUTTON : BE SURE THE DISTANCE

              FROM BOTTOM SIDE OF DOOR EDGE 

              TO BOTTOM OF BOTTOM LATCH 

              ASSEMBLY IS 13/32".

           2.Tighten screws to install bottom latch 

              assembly.

STEP 6 

INSTALL TOP LATCH ASSEMBLY

           1.Align vertical center line of top latch 

              assembly and upper connecting tube as 

              shown on template (B-1). Mark door as 

              indicated on template (B-1).

              CAUTION: BE SURE THE  DISTANCE

              FROM DOOR FRAME TO LINE

              W MUST BE 2"

           2.Tighten screws to install top latch assembly.

STEP 5 

INSTALL TOP STRIKE

           1.Align vertical center line of top strike and

              upper connecting tube as shown on template 

              (B-1).Mark door as indicated on template 

              (B-1).

           2.Tighten screws to install top strike with

              proper adjustment.

STEP 4

INSTALL DEVICE BODY

           1.Remove the head cover from the device

              body and end cover from the mounting 

              bracket by removing the screws that hold 

              them on.

           2.Align tailpiece receiver of exit device and

              trim/cylinder tailpiece, so it slides onto 

              trim/cylinder tailpiece. Also align screw 

              holes on exit device head with mounting

              holes on the door.

           3.Install and tighten the mounting screws 

              for the head of the exit device and end

              cover mounting bracket.

Summary of Contents for F2000V Series

Page 1: ...F FIRE RATED EXIT DEVICE 2012 03 ...

Page 2: ...hown on template Mark door as indicated on template B 2 CAUTTON BE SURE THE DISTANCE FROM BOTTOM SIDE OF DOOR EDGE TO BOTTOM OF BOTTOM LATCH ASSEMBLY IS 13 32 2 Tighten screws to install bottom latch assembly STEP 6 INSTALL TOP LATCH ASSEMBLY 1 Align vertical center line of top latch assembly and upper connecting tube as shown on template B 1 Mark door as indicated on template B 1 CAUTION BE SURE ...

Page 3: ... 4 dia 1 1 8 deep 5 Hammer 3 anchors into 3 anchor screw holes Tighten up 3 screws STEP 13 INSTALL 4 COVERS Install head cover end cover top latch cover bottom latch cover and tighten screws STEP 8 INSTALL AND ADJUST UPPER CONNECTING TUBE 1 Keep the end of the tube with the threaded insert upward to connect it with the threaded bolt in the top latch assembly 2 Connect the other end of the tube to ...

Page 4: ...Round Head 1 4 x 1 6 PCS Wood Screws Wood Screws Flat Head Floor Strike Thru Bolt 12 PCS Machine Screws Machine Screws Flat Head 1 4 20P x 3 4 12 PCS 1 4 20P x 3 4 3 PCS 14 x1 1 2 15 PCS Machine Screws Self Tapping Flat Head 5 32 x3 4 3 PCS 1 4 x 1 3 PCS Anchor Assembly 1 Assembly IF DOOR IS LESS THAN 36 REMOVE END COVER AND CUT SECTION A TO DESIRED LENGTH ...

Page 5: ...e B For F2000V Fire Rated Drill 9 32 holes inside and 3 8 holes outside for the 6 thru bolts Round Head Screws 1 4 20P x 3 4 x 6 Round Head Screws 2012 03 3 4 for LE 08 LE 08A Trim 3 4 for LE 08 LE 08A Trim 2 3 4 2 3 4 When installing 1000R x 1000V on a pair of doors a Double Door Strike DDS is required For complete template information please refer to the DDS template CENTER LINE CENTER LINE ...

Page 6: ...e and install screw but do not tighten all the way 2 Drill 2 D holes and install and tighten screws 3 Tighten screw in hole E all the way 2012 03 TEMPLATE B 2 A For 2000V Series UL Listed Drill tap for 3 1 4 20P x 3 4 machine screws 2xD E for latches Drill 3 3 16 pilot holes 2xD E for self tapping machine screws or wood screws for latches B For F2000V Fire Rated Drill 9 32 holes 2xD E inside and 3...

Page 7: ...ll the way 2 Make sure distance from door frame to line W is 2 3 Drill 2 D holes and install and tighten screws 4 Tighten screw in hole E all the way A For 2000V Series UL Listed Drill tap for 3 1 4 20P x 3 4 machine screws 2xD E for latches Drill 3 7 32 pilot holes 2xD E for self tapping machine screws or wood screws for latches B For F2000V Fire Rated Drill 9 32 holes 2xD E inside and 3 8 holes ...

Reviews: